Yaskawa J50M Instructions User Manual

Page 157

Advertising
background image

#6050 to #6055

#6056 to #6o6l

#6062

(Skip)

#6063 (Skip)

#6156 to #6161

#6280 to #6284

#6286 to #6290

#6292 to #6296

#6298 to #6302

#6400 to #6404

#6406 to #6411

#6444 to #6448

#6450 to #6454

#6456 to #6411

(Servo control)

(PG multiplication factor)

(Error detect area)

(Rapid traverse rate)

(Linear

time 1)

(2-step

switch speed)

(Linear

time 2)

(Backlash compensation amount)

(Move amount/ motor rotation)

(Minimum move amount)

(Servo input gain)

( K p )

. After reading-in of parameter tape

4.3.8 INTERNALTOGGLE SWITCHES

The following switches maybe easily turned on and

offonthe NC operator’s panel even when they cannot
be operated on the machine control station. Setting
numbers and their contents are as follows.

7

6

5

4

3

2

1

0

o

0

1

1

I

I

#6002

7

6

5

4

3

2

1

0

0

0

0

0

0

0

1

b l o c k

‘ S t a r t

lock

*Optional block skip

‘ D r y r u n

I

I

‘Optional stop

I

lock

‘Auxiliary function lock

Setting data

Machine’s switch

Result on/off

“O” = OFF

OFF

OFF

ON

ON

OFF

ON

ON

ON

The functions of the internal toggle switches work

only when parameter #6006D3 = 1 (internal toggle

function on).

off, only the

the machine control panel work.

4.3.9 OPERATION TIME DISPLAY

The system counts the duration of automatic

operation and it can be displayed. This function
permits the display of the time it has been taken for a
piece of work or the total operational time of the
system.

1.

2.

Procedure of display

Depress the ALM key, then select a screen
of running time with the PAGE key as

+

shown below.

Three kinds of operation time will be dis-
played in hours, minutes, and seconds.

Top :

Total operating time after

Middle :

Total operating time of CYCLE
START

Bottom:

Total operating time of FEED

Resetting display

Each operation time display can be reset inde-
pendently by the following procedure.

When operating times are displayed :

A .

POWER ON time at the top
will be reset

CYCLE START time in the

middle will be reset.

c .

FEED time at the bottom
will be reset

The timers of operation time preserve data unless
they are reset, even after power is turned off.

If the machine control station is provided with the

switches that turn on and off the above machine
functions, the state of a switch on the machine’s
control panel is ORed with that of the NC operator’s
panel will determine the machine condition.

149