Yaskawa J50M Instructions User Manual

Page 169

Advertising
background image

4.7.5 OPERATIONS USING DATA

INTERFACE

The use of data input/output interface allows the

following operations and runs:

(1) The input /output operations of tool offset

amounts,

setting data, and parameter data and

the output operations (punch out) of part pro-

grams. For details, see 4.4, “TAPE INPUT/
OUTPUT OPERATIONS

OF NC

DATA.

(2) The storing of part programs into memory.

For details, see 4.5, “LOADING PART PROGRAMS
INTO MEMORY’.

(3) Tape-verification of part programs, tool off-

set amount, setting data, and parameter data,
For details, see 4.8,

4.8 TAPE VERIFYING

The punched tape of the data shown below
be

compared to

memory to check if

.

Part program

. Tool

. Setting

contents of the NC internal

they match.

parameter

The punched tape is entered through the NC tape

reader or the data input/output interface (option). For
the methods of setting the input/output equipment (set-
ting #6003) and the baud rate (parameters #6026
through #6029), refer to 4.7 “SUPPLEMENT TO DATA
INPUT/OUTPUT INTERFACE

The following descrip-

tion is made assuming that this option is installed.

4.8.1

SETTING AND PARAMETER TAPE VERIFYING

1.

2.

3.

5.

6.

Select “ 1“ of system No. switch.

Set the MODE SELECT switch to the EDIT.

Depress PRM function key.

Depress RESET key.

Load the NC tape via tape reader.

Depress VER key.

Tape starts, and the contents of tape and
the contents of setting /parameter are veri-
fied.

blinks on the CRT.

If disagreement with the tape data is

ERROR” blinks on the

After completion of verifying without dis-
agreement , tape reader stops and

dis-

appears.

4.8.2 TOOL OFFSET VALUE TAPE VERIFYING

2.

3.

4.

5.

6.

4.8.3

(1)

a.

b.

c.

d.

e.

(2)

a.

b.

c.

d.

e.

Set the MODE SELECT switch to the EDIT.

Depress OFS function key.

Depress RESET key.

Load the source tape via tape reader .

Depress VER key

Tape starts , and the contents of tape and
the contents of tool offset values are verifi-
ed.

If disagreement with the tape data is

detected,

“INPUT ERROR” blinks on the

CRT .

After completion of verifying without dis-
agreement, tape reader stops and

disappears.

VERIFYING PART PROGRAM TAPE

Verifying a part program tape having pro-

gram number

Select the EDIT mode.

Depress the PROG function key .

Set the part program tape to the tape reader.

Depress the RESET key.

Depress the VER key.

The tape is

started to compare the

tents of the part program memory to the
contents of the part program tape.

During

this operation ,

blinks . If

a mismatch is found , “INPUT ERROR”
blinks on the CRT.

When a match is found and this operation is.
completed, the tape reader stops , upon
which

display erased.

Note:

By the operation of “RESET , VER, “

the verifying feature verifies the data from
the tape head to code.

Verifying a part program tape having no
program number

Select the EDIT mode .

Depress

PROG function key.

Set the part

to the tape reader.

Depress the RESET key .

Depress

key in program

number.

161

Advertising