4.4 MP2000 Series Machine Controller Parameter Details

4.4.2 Motion Setting Parameter Details

4-43

Motion Parameters

Related parameters

• Setting parameters

SERVOPACK Parameter Setting

The actual torque limit is the lowest one of the values listed in a category in the following table.

For linear servomotors, the parameter numbers are different. Use Pn482 instead of Pn402 and Pn483 instead of
Pn403.

( 13 ) Secondly Speed Compensation

Register No.

Name

Setting Range

Default Value

Setting Unit

Remarks

OL

14

Positive Side Limiting
Torque/Thrust
Setting at the Speed Ref-
erence

–2

31

to 2

31

–1

30000

1 = 0.01%
or 0.0001%

To enable the setting, the
SERVOPACK parameter
also needs to be set.

Pn002 Setting

Forward Torque Limit

Reverse Torque Limit

When OPTION.P_CL = 0 When OPTION.P_CL = 1 When OPTION.N_CL = 0 When OPTION.N_CL = 1

n.

0

or
n.

2

Pn402 setting

Pn402 setting,
Pn404 setting

Pn403 setting

Pn403 setting value,
Pn405 setting value,

n.

1

Pn402 setting,
PTLIM (TLIM)

Pn402 setting,
Pn404 setting,
PTLIM (TLIM)

Pn403 setting,
NTLIM (TLIM)

Pn403 setting value,
Pn405 setting value,
NTLIM (TLIM)

n.

3

Pn402 setting

Pn402 setting,
Pn404 setting,
PTLIM (TLIM)

Pn403 setting

Pn403 setting value,
Pn405 setting value,
NTLIM (TLIM)

Positive Side Limiting

Torque/Thrust Setting

at the Speed Reference

OL

14

Torque limit input

Pn81F.1

= 2

The set value of PTLIM, NTLIM,

and TFF are ignored.

= 0

Pn002.0

= 3

= 1 PTLIM and NTLIM operate

as the torque limit values.

TFF operates as the torque feed

forward.

When P-CL and N-CL are available,

PTLIM and NTLIM operate

as the torque limit value.

OL

16

Secondly Speed Compensation

Setting Range

Setting Unit

Default Value

−2

31

to 2

31

−1

Depends on the speed
unit set in Function Set-
ting 1 (setting parameter
OW

03, bits 0 to 3).

0

Description

Set the speed feed forward amount for the Phase Reference (PHASE), Interpolation (INTERPOLATE), and Latch
(LATCH) commands.

The setting unit for Speed Compensation (setting parameter OW

31) is 0.01% (fixed). The unit for this parameter,

however, can be selected using Speed Unit Selection.
When used at the same time as OW

31, speed compensation can be performed twice.

The setting unit for this parameter depends on the Speed Unit Selection (OW

03, bits 0 to 3), but

the result of applying the speed unit setting is not shown here.