8.1 Position Control

8.1.2 Control Block Diagram for Position Control

8-7

Control Block Diagrams

Filter

Analog monitor value

Pn109

Pn10A

Pn102

Pn101

A

B

Pn100

A

B

M

PG

Pn11F

A

B

Speed Loop Gain

Position Loop Gain

Pn811 or Pn812

(OW

3A)

(OW

32)

(OW

30)

(OW

2F)

S

Kp

Ti

(OW

2E)

(OW

34)

Kv

NTi

FB

Vref

SERVOPACK

NS100/NS115

MPOS

APOS

LPOS

TRQ

B

A

Counter

Latch signal

Counter

POSING

command

Acceleration/

deceleration

processing

Acceleration:

Pn80B (OL

36)

Deceleration:

Pn80E (OL

38)

INTERPOLATE

command

Differ-

ential

Speed Feed Forward

Compensation

Position Integration

Time Constant

Speed Integration

Time Constant

Current

loop