Absolute position detection – Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual

Page 362

Advertising
background image

9.4 Absolute Position Detection for Infinite Length Axes

9.4.5 Infinite Length Position Control without Simple Absolute Positions

9-25

Absolute Position Detection

Use the following flowchart for storing the position data in the setting parameters and for requesting to load the infinite
length axis position information.

High-speed scan drawing

starts

1st scan after the drawing starts ? Or,

Servo power reset signal is set to 1?

Position Data Re-setup Request Flag is set to 1

Operation ready and Position Data

Re-setup Request Flag is set to 1 ?

ABS System Infinite Length Position

Control Data Initialization Completed

Flag is set to 0 ?

Toggle Buffer Enabled Flag is set to 1 ?

Toggle Buffer Selection Flag is

set to 1 ?

Copy the value of Buffer 1 and

paste it in the setting

parameter.

ABS System Infinite Length

Position Control Data Initialization

Request Flag is set to 1

Position Data Save Request Flag is

set to 1

Copy the value of Buffer 0 and

paste it in the setting

parameter.

End of

high-speed scan drawing

ABS System Infinite Length

Position Control Data Initialization

Request Flag is set to 0

Position Data Re-setup Request Flag is set to 0

NO

YES

NO

YES

NO

YES

NO

YES

NO

YES

Position Data Re-setup Enabled Flag is

set to 0