10.4 Motion Parameter Details

10.4.3 Monitoring Parameter List

10-42

IW

40

User Constant
Reading Data 3

Range: 0 to 65535

Displays the value read out by executing the com-
mand Read User Constant. Valid when Inverter User
Constant Number Size (OW

3D) = 3 or 4.

IW

41

User Constant
Reading Data 4

Range: 0 to 65535

Displays the value read out by executing the com-
mand Read User Constant. Valid when Inverter User
Constant Number Size (OW

3D) = 4.

IW

42

Auxiliary Inverter User Constant Number

Range: 0 to 65535

Displays the auxiliary inverter user constant number
set for the subcommand Read User Constant or Write
User Constant.

IW

43

−

Reserved by the system.

IW

44

Auxiliary User Constant
Reading Data 1

Range: 0 to 65535

Displays the value read out by executing the subcom-
mand Read User Constant. Valid when Auxiliary
Inverter User Constant Number Size (OW

43) = 1

to 4.

IW

45

Auxiliary User Constant
Reading Data 2

Range: 0 to 65535

Displays the value read out by executing the subcom-
mand Read User Constant. Valid when Auxiliary
Inverter User Constant Number Size (OW

43) = 2

to 4.

IW

46

Auxiliary User Constant
Reading Data 3

Range: 0 to 65535

Displays the value read out by executing the subcom-
mand Read User Constant. Valid when Auxiliary
Inverter User Constant Number Size (OW

43) = 3

or 4.

IW

47

Auxiliary User Constant
Reading Data 4

Range: 0 to 65535

Displays the value read out by executing the subcom-
mand Read User Constant. Valid when Auxiliary
Inverter User Constant Number Size (OW

43) = 4.

IL

48

Fixed Parameter Monitor

Displays the fixed parameter value read out by execut-
ing the subcommand Read Fixed Parameters.

IW

4A

to

IW

4F

−

Reserved by the system.

IW

50

to

IW

5F

Inverter/Type

Displays the connected Inverter model.

IW

60

to

IW

67

Inverter/Software Version (Communication Board)

Displays the software version number of the optional
communication board of the connected Inverter.

IW

68

to

IW

6F

Inverter/Software Version (Main)

Displays the software version number of the connected
Inverter.

IW

70

Transmission Reference
Input Data 0

Range: 0 to FFFFH

Displays the 1st word of the response data to the com-
mand Transmission Reference.

IW

71

Transmission Reference
Input Data 1

Range: 0 to FFFFH

Displays the 2nd word of the response data to the
command Transmission Reference.

IW

72

Transmission Reference
Input Data 2

Range: 0 to FFFFH

Displays the 3rd word of the response data to the
command Transmission Reference.

IW

73

Transmission Reference
Input Data 3

Range: 0 to FFFFH

Displays the 4th word of the response data to the
command Transmission Reference.

IW

74

Transmission Reference
Input Data 4

Range: 0 to FFFFH

Displays the 5th word of the response data to the
command Transmission Reference.

Register No.

Name

Contents