4 manually allocating inverters – Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual
Page 374

10.2 Operating Inverters Using an MPE720
10.2.4 Manually Allocating Inverters
10-10
10.2.4 Manually Allocating Inverters
1.
Start the MPE720 (version 5.12 or later) installed in the personal computer connected to the Machine
Controller, and open the Module Configuration Window.
2.
Right-click the SVB column in the Module Details field, and select MECHATROLINK
from the pop-up
menu.
The MECHATROLINK Definition Window for parameter setting will open.
3.
Click Link Assignment Tab to display the tab page.
4.
Click the
Button in the TYPE column, and select VS-7Series (Inverter) from the list.
Always select VS-7Series regardless of the actual inverter model.
5.
Select File - Save from the main menu to save the setting.
6.
Click the close button X to close the MECHATROLINK Definition Window and return to the Module
Configuration Window.