G.9 m-ii stepper parameters, A-32, 1 ) standard parameters – Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual

Page 521

Advertising
background image

Appendix G Settings when Connecting MECHATROLINK-II Compatible Stepping Motor Drivers

G.9 M-II Stepper Parameters

A-32

G.9

M-II Stepper Parameters

( 1 ) Standard Parameters

Details on the parameters No. 0 (Parameter Switch) to 4 (Memory Switch 4) are described in the following pages.

No.

Name

Size (Byte)

Unit

0

Parameter Switch

2

Bit

1

Memory Switch 1

2

Bit

2

Memory Switch 2

2

Bit

3

Memory Switch 3

2

Bit

4

Memory Switch 4

2

Bit

5

Electronic Gear (Numerator)

2

Bit

6

Electronic Gear (Denominator)

2

Bit

7

Basic Resolution

2

pulse/rev

8

Zero Point Position Range

2

Reference unit

9

Home Offset (For Absolute Encoder)

4

Reference unit

10

Positioning Completed Width

2

Reference unit

11

Positioning Completed Width 2 (NEAR)

2

Reference unit

12

Forward Software Limit

4

Reference unit

13

Reserve Software Limit

4

Reference unit

14

Start Speed

2

100 reference units

15

Linear Acceleration Constant (Acceleration
Rate)

2

10000 reference units

16

Linear Deceleration Constant (Deceleration
Rate)

2

10000 reference units

17

External Positioning Move Distance

4

Reference unit

18

Zero Point Return Approach Speed

2

100 reference units/s

19

Zero Point Return Creep Speed

2

100 reference units/s

20

Home Offset (Home Offset)

4

Reference unit

21

Current at Run

2

%

22

Current at Stop

2

%