3.4 Self-configuration and Definition Files

3.4.5 Precautions When Saving SERVOPACK Parameters

3-33

Self-configuration and Created Definition Files

( 7 ) Saving Data to Flash Memory

The data flow for SERVOPACK parameters is as follows when saving the parameters to flash memory on the MPE720:

• The Machine Controller writes the parameters data (Input Data) held in SDRAM to flash memory.

Save to flash memory also after having changed set data of SERVOPACK parameter.

indicates data has been written.

3.4.5 Precautions When Saving SERVOPACK Parameters

Before executing saving operation in the SERVOPACK Tab Page in any cases excluding the SERVOPACK replace-
ment, always select Edit - Copy Current Value to copy the values in Current to Input Data.

MECHATROLINK

RAM

EEP

-ROM

SRAM

SDRAM

Input

Data

MPE720 㧔online㧕

HDD in personal computer

Display

Current

Value

Input

Data

Flash

Memory

System

Software

Control

Software

SERVOPACK Parameters

(All Axes)

Parameters

SERVOPACK

SERVOPACK

Send Send

Machine Controller