4 ) timing charts, B ] monitoring parameters, A ] normal end [ b ] error end – Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual

Page 216

Advertising
background image

6.2 Motion Command Details

6.2.9 Change Acceleration Time (ACC)

6-55

Motion Commands

[ b ] Monitoring Parameters

( 4 ) Timing Charts

[ a ] Normal End

[ b ] Error End

Parameter

Name

Monitor Contents

IL

02

Warning

Stores the most current warning.

IL

04

Alarm

Stores the most current alarm.

IW

08

Motion Command
Response Code

Indicates the motion command that is being executed.
The response code will be 10 during ACC command execution.

IW

09

Bit 0

Command Execution
Flag

Turns ON during ACC command execution and turns OFF when execution has been
completed.

IW

09

Bit 1

Command Hold
Completed

Always OFF for ACC command.

IW

09

Bit 3

Command Error
Completed Status

Turns ON if an error occurs during ACC command execution. Turns OFF when another
command is executed.

IW

09

Bit 8

Command Execution
Completed

Turns ON when ACC command execution has been completed.

OW

08 = 10 (ACC)

IW

08 = 10 (ACC)

IW

09, bit 0 (BUSY)

IW

09, bit 8 (COMPLETE)

IW

09, bit 3 (FAIL)

Undefined length

of time

OW

08 = 10 (ACC)

IW

08 = 10 (ACC)

IW

09, bit 0 (BUSY)

IW

09, bit 8 (COMPLETE)

IW

09, bit 3 (FAIL)

Undefined length

of time

Advertising