6.2 Motion Command Details

6.2.13 Change Speed Loop Gain (KVS)

6-63

Motion Commands

( 4 ) Timing Charts

[ a ] Normal End

[ b ] Error End

IW

09

Bit 8

Command Execution
Completed

Turns ON when KVS command execution has been completed.

(cont’d)

Parameter

Name

Monitor Contents

OW

08 = 14 (KVS)

IW

08 = 14 (KVS)

IW

09, bit 0 (BUSY)

IW

09, bit 8 (COMPLETE)

IW

09, bit 3 (FAIL)

Undefined length

of time

OW

08 = 14 (KVS)

IW

08 = 14 (KVS)

IW

09, bit 0 (BUSY)

IW

09, bit 8 (COMPLETE)

IW

09, bit 3 (FAIL)

Undefined length

of time