4.4 MP2000 Series Machine Controller Parameter Details

4.4.2 Motion Setting Parameter Details

4-57

Motion Parameters

( 32 ) Absolute Infinite Length Axis Position Control Information

( 33 ) Command Buffer for Servo Driver Transmission Reference Mode

OL

5E

Encoder Position when Power is OFF

(Lower 2 words)

Setting Range

Setting Unit

Default Value

-2

31

to 2

31

−1

pulse

0

Description

This is the information for infinite length axis position control when an absolute encoder is used.

The encoder position is stored in 4 words.
If the Request ABS Rotary Pos LOAD bit is set to 1 in the RUN Command Setting (setting parameter OW

00, bit 7),

the position information will be recalculated with the values set here and the Pulse Position when Power is OFF
(OL

62 and OL

64).

Refer to 9.4 Absolute Position Detection for Infinite Length Axes for details.
Set to 0 for linear type.

OL

60

Encoder Position when Power is OFF

(Upper 2 words)

Setting Range

Setting Unit

Default Value

-2

31

to 2

31

−1

pulse

0

Description

Same as for OL

5E.

Refer to

9.4 Absolute Position Detection for Infinite Length Axes for details.

Set to 0 for linear type.

OL

62

Pulse Position When Power is OFF (Lower 2 words)

Setting Range

Setting Unit

Default Value

-2

31

to 2

31

−1

pulse

0

Description

This is the information for infinite length axis position control when an absolute encoder is used.

The axis position in pulses managed internally by the controller is stored in 4 words.
If the Request ABS Rotary Pos. LOAD bit is set to 1 in the Run Command Setting (setting parameter OW

00, bit 7),

the position information will be recalculated with the values set here and the Encoder Position when Power is OFF
(OL

5E and OL

60).

Refer to 9.4 Absolute Position Detection for Infinite Length Axes for details.
Set to 0 for linear type.

OL

64

Pulse Position When Power is OFF (Upper 2 words)

Setting Range

Setting Unit

Default Value

-2

31

to 2

31

−1

pulse

0

Description

Same as for OL

62.

Refer to 9.4 Absolute Position Detection for Infinite Length Axes

for details.

Set to 0 for linear type.

OW

70 to OW

7E

Command Buffer for Servo Driver Transmission

Reference Mode

Setting Range

Setting Unit

Default Value

0

Description

This area is used for response data when MECHATROLINK Servo commands are specified directly.

• MECHATROLINK-I and MECHATROLINK-II, 17-byte Mode: Data area = OW

70 to OW

77

• MECHATROLINK- II, 32-byte Mode: Data area = OW

70 to OW

7E

Position

Phase

Speed Torque

Position

Phase

Speed Torque

Position

Phase

Speed Torque

Position

Phase

Speed Torque

Position

Phase

Speed Torque

Advertising