2.1 LED Indicators and Switch Settings

2.1.3 SVB-01 Module Status Indication

2-3

Settings and Installation

: Lit

: Unlit

: Blinks

- : Not specified

Error

<In Master Mode>

Servo axis error occurred in one of the
servo axes.
(1) Warning (Check the parameter
IL

02.)

(2) Alarm (Check the parameter
IL

04.)

(3) Command error completed status
(Bit 3 of IW

09 is ON,

Bit 3 of IW

0B is ON)

<In Slave Mode>

MECHATROLINK communications
error

The indicated status differs depending on the mode,
Master or Slave.

<In Master Mode>

Indicates that an error has occurred in one of the servo
axes. Check the parameters shown on the left to find
what kind of error has occurred.

(1) Warning

The cause of the error is written in each bit of
IL

02. Find the cause and remove it. Reset the

alarm if necessary.

(2) Alarm

The cause of the error is written in each bit of
IL

04. Find the cause and remove it. Reset the

alarm if necessary.

(3) Command Error Completed Status

Indicates that an error has occurred during execu-
tion of a motion command or motion subcommand.
(Example: A command outside the setting range
was sent.)
Clear the command (OW

08, OW

0A).

<In Slave Mode>

A MECHATROLINK communication error has
occurred. Check the MECHATROLINK cable con-
nection.

No communication from the master

In slave mode, no communication from the master has
been received. Check the master station and the
MECHATROLINK cable connection.

Hardware error

1: -
2: ROM error
3. RAM error
4: CPU error
5: FPU error
6: Shared memory error
7: JL-080 error
(Number indicates the number of times
blinking)

Hardware failure of the SVB-01 Module occurred.
Replace the Module.

Software error

1: -
2: Watchdog time timeout
3: Address error (reading) exception
4: Address error (writing) exception
5: FPU exception
6: General illegal instruction exception
7: Slot illegal instruction exception
8: General FPU suppression exception
9: Slot FPU suppression exception

10: Watchdog time timeout (SVB)

(Number indicates the number of times
blinking)

Software failure of the SVB-01 Module occurred.
Replace the Module.

Status

Indication

SVB-01 Module Status

Description

RUN ERR