6.2 Motion Command Details

6.2.6 Jog Mode (FEED)

6-46

[ b ] Monitoring Parameters

Parameter

Name

Monitor Contents

SVR

IW

00

Bit 1

Running (At Servo
ON)

Indicates the Servo ON status.
1: Power supplied to Servomotor, 0: Power not supplied to Servomotor

IL

02

Warning

Stores the most current warning.

IL

04

Alarm

Stores the most current alarm.

IW

08

Motion Command
Response Code

Indicates the motion command that is being executed.
The response code is 7 during FEED command execution.

IW

09

Bit 0

Command
Execution Flag

Turns ON when abort processing is being performed for FEED command. Turns
OFF when abort processing has been completed.

IW

09

Bit 1

Command Hold
Completed

Always OFF for FEED command.

IW

09

Bit 3

Command Error
Completed Status

Turns ON if an error occurs during FEED command execution. The axis will decel-
erate to a stop if it is moving. Turns OFF when another command is executed.

IW

09

Bit 8

Command
Execution
Completed

Always OFF for FEED command.

IW

0C

Bit 0

Discharging
Completed

Turns ON when pulse distribution has been completed for the move command.
Turns OFF during execution of a move command.

IW

0C

Bit 1

Positioning
Completed

Turns ON when pulse distribution has been completed and the current position is
within the Width of Positioning Completion. OFF in all other cases.

IW

0C

Bit 3

NEAR Position

The operation depends on the setting of the NEAR Signal Output Width (setting
parameter OL

20).

OL

20 = 0: Turns ON when pulse distribution has been completed (DEN =

ON). Otherwise, it turns OFF.

OL

20

0: Turns ON when

the absolute value of the difference between

MPOS (IL

12) and APOS (IL

16) is less than the NEAR

Signal Output Width even if pulse distribution has not been com-
pleted.
OFF in all other cases.

R

R

R

R

R

R

R

R

R

R

R