3 ) when the servopack tab page is open – Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual

Page 70

Advertising
background image

3.4 Self-configuration and Definition Files

3.4.4 Current Value and Setting Data in SVB

3-27

Self-configuration and Created Definition Files

( 3 ) When the SERVOPACK Tab Page Is Open

The data flow for SERVOPACK parameters is as follows when the SERVOPACK Tab Page is open in the SVB Defini-
tion Window on the MPE720 (refer to 3.4.3 SVB Definition

for details on how to open the SERVOPACK Tab Page.):

• The MPE720 reads and displays the parameters that are held in the SERVOPACK’s RAM for the relevant axis to

the Current in the SERVOPACK Tab Page.
It also reads and displays the values that are held in the Machine Controller’s SDRAM values to the Input Data
in the SERVOPACK Tabbed page.

indicates data has been written.

The following figure shows an example of the SERVOPACK Tab in the SVB Definition Window. The values in Cur-
rent
are different from the values in Input Data.

SDRAM

SRAM

EEP

-ROM

RAM

MECHATROLINK

Input

Data

MPE720 (online)

HDD in personal computer

Display

Current

Value

Input

Data

Machine Controller

Send

Send

SERVOPACK

SERVOPACK

Control

Software

System

Software

Parameters

SERVOPACK

Parameters

(All Axes)

Flash

Memory

Advertising