3 ) detailed descriptions – Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual

Page 345

Advertising
background image

9.3 Absolute Position Detection for Finite Length Axes

9.3.1 Parameter Settings for Finite Length Axes

9-8

( 3 ) Detailed Descriptions

[ a ] Axis Selection (Machine Controller Fixed Parameter No.1, Bit 0)

This setting is used to select either an finite or infinite length axis.
Set to 0 when using the axis as a finite length axis.

[ b ] Encoder Type and Absolute Encoder Usage

For an axis performing absolute position detection, set the parameters as shown in the following table.

[ c ] Number of Pulses per Motor Rotation

Refer to the following table and set the fixed parameter 36 (Number of Pulses per Motor Rotation) according to the
number of servomotor (encoder) bits. The settings can be used for all SERVOPACK models.

[ d ] Max. Revolutions of Absolute Encoder/Multiturn Limit Setting

These parameters determine the maximum value of the number of encoder turns managed by the SERVOPACK and
Machine Controller.
The setting is determined by the SERVOPACK that is used and the type of axis (Machine Controller fixed parameter 1,
bit 0). Set the parameters as shown in the following table when using an axis as a finite length axis.

Model

Parameter

Setting

Machine Controller

Fixed parameter 30
(Encoder Selection)

1: Absolute encoder

Σ-II, Σ-III and

Σ-V Series

Parameter: Pn002.2
(Absolute Encoder Usage)

0: Uses absolute encoder as an absolute encoder.

Σ-I Series

Parameter: Cn-0001 Bit E
(Encoder Type)

1: Absolute encoder

If the above settings are not used, correct motion control will not be performed. Set the parameters carefully.
Be sure to set both the Machine Controller and SERVOPACK parameters.

Number of Bits

Machine Controller

Fixed Parameter 36

(Number of Pulses per Motor Rotation)

12

4096

13

8192

15

32768

16

65536

17

131072

20

1048576

If the above settings are not used, correct motion control will not be performed. Set the parameters carefully.

Applicable

SERVOPACK

Machine Controller

Fixed Parameter 38

(Maximum Number of Absolute Encoder

Turns Rotation)

SERVOPACK

Parameter Pn205

(Multiturn Limit Setting)

Σ-II, Σ-III and

Σ-V Series

65535

65535

Σ-I Series

99999

If the above settings are not used, the position may be offset. Set the parameters carefully.

Advertising