11.2 Overtravel Function

11.2.2 Connections to

Σ-I Series SGDB or SGD SERVOPACK

11-11

Utility Functions

11.2.2 Connections to

Σ-I Series SGDB or SGD SERVOPACK

The following parameters must be set to ensure the overtravel input signals are connected correctly for the overtravel
function.

( 1 ) Overtravel Input Signal Connections

Connect the input signals for the overtravel limit switches to the corresponding pins on the SERVOPACK CN1 or 1CN
connector as shown below.

Connections to SGDB and SGD SERVOPACK

Zero-clamp

Coasting

Pn001.1 = 1 or 2

Pn001.1 = 0

Overtravel

Stopping method

After stopping

Pn001.1 setting

Coast to a stop

Pn001.0 = 0 or 1

Pn001.0 = 2

Coasting

0

1

2

Dynamic

brake stop

Deceleration

stop

P-OT

When ON
1CN-7 is low.

Forward drive enabled.
Normal operating condition

When OFF
1CN-7 is high.

Forward drive disabled.
(Reverse movement possible.)

N-OT

When ON
1CN-8 is low.

Reverse drive enabled.
Normal operating condition

When OFF
1CN-8 is high.

Reverse drive disabled.
(Forward movement possible.)

Forward rotation

Reverse rotation

SERVOPACK

CN1-42

CN1-43

N-OT

P-OT

Servomotor

Negative

overtravel

Positive

overtravel