Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual

Page 372

Advertising
background image

10.2 Operating Inverters Using an MPE720

10.2.3 Operation Procedure

10-8

If required, set the Output Data Option Selection (OW

0C) and Input Data Option Selection (OW

0D) to enable

the data outputs of OW

13 to OW

16 and data inputs of IW

13 to IW

1D.

Refer to 10.2.5 I/O Options for details on Output Data Option Selection and Input Data Option Selection.

The output and input data that can be set during inverter operation are described below.

Output Data for Inverter Drive Control (Setup Parameters Tab Page)

* 1. Output data that is always available during inverter control operation
* 2. Data that is available when Output Data Option Selection (OW

0C) is selected while the command Inverter

Drive Control is being executed, or when Auxiliary Output Data Option Selection (OW

0E) is selected while the

subcommand Inverter I/O Control is being executed.

The subcommand Inverter I/O Control is valid only in MECHATROLINK-II 32-byte mode.
If the command Inverter Drive Control is switched to another command during its execution, the Inverter retains the
last data and continues operation. The MPE720 retains the last data of the monitoring parameters since inputs and
outputs between SVB Module and Inverter are stopped. The monitoring parameter Status, however, will be updated
for any command being executed except Transmission Reference.
The output data that can be used depends on the Inverter model. Refer to 10.4.4 Inverter Output Data Details for
details.

*1

*2

Advertising