Appendix B Settings When Connecting MECHATROLINK Compatible I/O Modules, MYVIS, and MP940

B.2 I/O Register Configuration

A-7

Appendices

B.2

I/O Register Configuration

This section describes the I/O register configuration of each MECHATROLINK compatible Module.

( 1 ) 120DRA83030, 120DAO83330, and JAPMC-IO2950-E (8-point Output)

( 2 ) 120DAI53330 and 120DAI73330 (8-point Input)

( 3 ) 120DDI34330 and JAPMC-IO2900-E (16-point Input)

( 4 ) 120DDO34340 and JAPMC-IO2910-E (16-point Output)

( 5 ) JAPMC-IO2920-E (16-point I/O)

( 6 ) JEPMC-IO350, JEPMC-IO2310, and JEPMC-IO2330 (64-point I/O)

Command

Data

High-speed/
Low-speed
control data
(1 word)

Response

Data

OW

None

Command

Data

Response

Data

High-speed/
Low-speed
control data
(1 word)

None

IW

Command

Data

Response

Data

High-speed/
Low-speed
control data
(1 word)

None

IW

Response

Data

High-speed/
Low-speed
control data
(1 word)

Response

Data

OW

None

Response

Data

High-speed/
Low-speed
control data
(1 word)

Response

Data

High-speed/
Low-speed
control data
(1 word)

OW

IW

Command

Data

Response

Data

OW

High-speed/
Low-speed
control data
(4 words)

IW

High-speed/
Low-speed
control data
(4 words)

OW

+1

IW

+1

OW

+2

IW

+2

OW

+3

IW

+3