A-34 – Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual

Page 523

Advertising
background image

Appendix G Settings when Connecting MECHATROLINK-II Compatible Stepping Motor Drivers

G.9 M-II Stepper Parameters

A-34

( 4 ) No. 2: Memory Switch 2

( 5 ) No. 3: Memory Switch 3

( 6 ) No. 4: Memory Switch 4

Bit

Name

Setting

0

Reverse Rotation Mode (Rotation Direction)

0

CCW as forward rotation

1

CW as forward rotation

1 to 5

Undefined

6

Positive Software Limit Check

0

No check

1

Check

7

Negative Software Limit Check

0

No check

1

Check

8 to 15

Undefined

Bit

Name

Setting

0 to 9

Undefined

10

MECHATROLINK Communication Check
(For Debugging)

0

With communication check

1

Without communication check
Ignores the command errors 01, 02, and 03.

11

WDT Check (For Debugging)

0

With WDT check

1

Without WDT check
Ignores error 04.

12

Communication Error Count

0 to F

Communication error processing will be imple-
mented when received errors (timeout and CRC
error) occur continuously a set number of
times.

• Processing to a safe stop, such as power dis-

connection and excitation OFF.

• 0: Select a value from the options specified

for the system.

• Valid only for transmission in a single direc-

tion.

13
14

15

Bit

Name

Setting

0

Undefined

1

Home Direction

0

Forward direction

1

Reverse direction

2 to 8

Undefined

9

Brake ON/OFF (Optional)

0

Use BRK_ON and BRK_OFF commands.

1

BRK_ON/BRK_OFF command disabled.

10

P-OT Signal Logic

0

Positive logic

1

Negative logic

11

N-OT Signal Logic

0

Positive logic

1

Negative logic

12

DEC Signal Logic

0

Positive logic

1

Negative logic

13 to 15

Undefined