Appendix G Settings when Connecting MECHATROLINK-II Compatible Stepping Motor Drivers

G.7 Automatic Parameter Updating Function

A-30

G.7

Automatic Parameter Updating Function

( 1 ) Parameters Updated when a MECHATROLINK Connection Is Established

(Machine Controller to Stepper)

When communication is in MECHATROLINK-II 32-byte mode and the User Constants Self-writing
Function bit (fixed parameter No. 1, bit 10) is set to 0 (enabled)

Only when using standard parameters.

( 2 ) Parameters Updated when a Setting Parameter is Changed

(Machine Controller to Stepper)

When communication is in MECHATROLINK-II 32-byte mode and the User Constants Self-writing
Function bit (fixed parameter No. 1, bit 10) is set to 0 (enabled)

The above parameters will also be automatically updated when Acceleration/Deceleration Degree Unit Selection bits
(OW

03, bits 4 to 7) is changed.

Only when using standard parameters

( 3 ) Parameters Updated When Execution of Motion Command Starts

(Machine Controller to Stepper)

In any communication mode when the User Constants Self-writing Function bit (fixed parameter No.
1, bit 10) is set to 0 (enabled)

Only when using standard parameters

In any communication mode, regardless of the setting of fixed parameter No. 1, bit 10

Only when using standard parameters

Machine Controller/Setting Parameter

M-II Stepper/Parameter

Straight Line Acceleration/

Acceleration Time Constant

OL

36

→

No.15

Straight Line Deceleration/Decel-

eration Time Constant

OL

38

→

No.16

Machine Controller/Setting Parameter

M-II Stepper/Parameters

Straight Line Acceleration/

Acceleration Time Constant

OL

36

→

No.15

Straight Line Deceleration/Decel-

eration Time Constant

OL

38

→

No.16

Machine Controller/Setting Parameter

M-II Stepper/Parameter

Straight Line Acceleration/

Acceleration Time Constant

OL

36

→

No.15

Updated when execution of POSING,
EX_POSING, ZRET, FEED, or STEP starts

Straight Line Deceleration/Decel-

eration Time Constant

OL

38

→

No.16

Updated when execution of POSING,
EX_POSING, ZRET, FEED, or STEP starts

Machine Controller/Setting Parameter

M-

II Stepper/Parameter

Approach Speed

OL

3E

→

No.18

Updated when execution of ZRET starts

Creep Rate

OL

40

→

No.19

Updated when execution of ZRET starts

Zero Point Return Travel

Distance

OL

42

→

No.20

Updated when execution of ZRET starts

External Positioning Final Travel

Distance

OL

46

→

No.17

Updated when execution of EX_POSING
starts

Advertising