G.7 automatic parameter updating function, A-30 – Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual

Page 519

Advertising
background image

Appendix G Settings when Connecting MECHATROLINK-II Compatible Stepping Motor Drivers

G.7 Automatic Parameter Updating Function

A-30

G.7

Automatic Parameter Updating Function

( 1 ) Parameters Updated when a MECHATROLINK Connection Is Established

(Machine Controller to Stepper)

When communication is in MECHATROLINK-II 32-byte mode and the User Constants Self-writing
Function bit (fixed parameter No. 1, bit 10) is set to 0 (enabled)

Only when using standard parameters.

( 2 ) Parameters Updated when a Setting Parameter is Changed

(Machine Controller to Stepper)

When communication is in MECHATROLINK-II 32-byte mode and the User Constants Self-writing
Function bit (fixed parameter No. 1, bit 10) is set to 0 (enabled)

The above parameters will also be automatically updated when Acceleration/Deceleration Degree Unit Selection bits
(OW

03, bits 4 to 7) is changed.

Only when using standard parameters

( 3 ) Parameters Updated When Execution of Motion Command Starts

(Machine Controller to Stepper)

In any communication mode when the User Constants Self-writing Function bit (fixed parameter No.
1, bit 10) is set to 0 (enabled)

Only when using standard parameters

In any communication mode, regardless of the setting of fixed parameter No. 1, bit 10

Only when using standard parameters

Machine Controller/Setting Parameter

M-II Stepper/Parameter

Straight Line Acceleration/

Acceleration Time Constant

OL

36

No.15

Straight Line Deceleration/Decel-

eration Time Constant

OL

38

No.16

Machine Controller/Setting Parameter

M-II Stepper/Parameters

Straight Line Acceleration/

Acceleration Time Constant

OL

36

No.15

Straight Line Deceleration/Decel-

eration Time Constant

OL

38

No.16

Machine Controller/Setting Parameter

M-II Stepper/Parameter

Straight Line Acceleration/

Acceleration Time Constant

OL

36

No.15

Updated when execution of POSING,
EX_POSING, ZRET, FEED, or STEP starts

Straight Line Deceleration/Decel-

eration Time Constant

OL

38

No.16

Updated when execution of POSING,
EX_POSING, ZRET, FEED, or STEP starts

Machine Controller/Setting Parameter

M-

II Stepper/Parameter

Approach Speed

OL

3E

No.18

Updated when execution of ZRET starts

Creep Rate

OL

40

No.19

Updated when execution of ZRET starts

Zero Point Return Travel

Distance

OL

42

No.20

Updated when execution of ZRET starts

External Positioning Final Travel

Distance

OL

46

No.17

Updated when execution of EX_POSING
starts

Advertising