G.7 automatic parameter updating function, A-30 – Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual
Page 519

Appendix G Settings when Connecting MECHATROLINK-II Compatible Stepping Motor Drivers
G.7 Automatic Parameter Updating Function
A-30
G.7
Automatic Parameter Updating Function
( 1 ) Parameters Updated when a MECHATROLINK Connection Is Established
(Machine Controller to Stepper)
When communication is in MECHATROLINK-II 32-byte mode and the User Constants Self-writing
Function bit (fixed parameter No. 1, bit 10) is set to 0 (enabled)
Only when using standard parameters.
( 2 ) Parameters Updated when a Setting Parameter is Changed
(Machine Controller to Stepper)
When communication is in MECHATROLINK-II 32-byte mode and the User Constants Self-writing
Function bit (fixed parameter No. 1, bit 10) is set to 0 (enabled)
The above parameters will also be automatically updated when Acceleration/Deceleration Degree Unit Selection bits
(OW
03, bits 4 to 7) is changed.
Only when using standard parameters
( 3 ) Parameters Updated When Execution of Motion Command Starts
(Machine Controller to Stepper)
In any communication mode when the User Constants Self-writing Function bit (fixed parameter No.
1, bit 10) is set to 0 (enabled)
Only when using standard parameters
In any communication mode, regardless of the setting of fixed parameter No. 1, bit 10
Only when using standard parameters
Machine Controller/Setting Parameter
M-II Stepper/Parameter
Straight Line Acceleration/
Acceleration Time Constant
OL
36
→
No.15
Straight Line Deceleration/Decel-
eration Time Constant
OL
38
→
No.16
Machine Controller/Setting Parameter
M-II Stepper/Parameters
Straight Line Acceleration/
Acceleration Time Constant
OL
36
→
No.15
Straight Line Deceleration/Decel-
eration Time Constant
OL
38
→
No.16
Machine Controller/Setting Parameter
M-II Stepper/Parameter
Straight Line Acceleration/
Acceleration Time Constant
OL
36
→
No.15
Updated when execution of POSING,
EX_POSING, ZRET, FEED, or STEP starts
Straight Line Deceleration/Decel-
eration Time Constant
OL
38
→
No.16
Updated when execution of POSING,
EX_POSING, ZRET, FEED, or STEP starts
Machine Controller/Setting Parameter
M-
II Stepper/Parameter
Approach Speed
OL
3E
→
No.18
Updated when execution of ZRET starts
Creep Rate
OL
40
→
No.19
Updated when execution of ZRET starts
Zero Point Return Travel
Distance
OL
42
→
No.20
Updated when execution of ZRET starts
External Positioning Final Travel
Distance
OL
46
→
No.17
Updated when execution of EX_POSING
starts