8.4 Speed Control

8.4.1 Motion Parameters for Speed Control

8-23

Control Block Diagrams

( 3 ) Monitoring Parameters

No.

Name

Unit

Default

Value

Range

IW

00

RUN Status

−

−

Bit setting

IW

01

Parameter Number When Range Over is
Generated

−

−

0 to 65535

IL

02

Warning

−

−

Bit setting

IL

04

Alarm

−

−

Bit setting

IW

08

Motion Command Response Code

−

−

0 to 65535

IW

09

Motion Command Status

−

−

Bit setting

IW

0A

Motion Subcommand Response Code

−

−

0 to 65535

IW

0B

Subcommand Status

−

−

Bit setting

IW

0C

Position Management Status

−

−

Bit setting

IL

0E

Target Position in Machine Coordinate
System (TPOS)

Reference unit

−

-2

31

to 2

31

−1

IL

10

Calculated Position in Machine
Coordinate System (CPOS)

Reference unit

−

-2

31

to 2

31

−1

IL

12

Machine Coordinate System Reference
Position (MPOS)

Reference unit

−

-2

31

to 2

31

−1

IL

14

CPOS for 32bit (DPOS)

Reference unit

−

-2

31

to 2

31

−1

IL

16

Machine Coordinate System Feedback
Position (APOS)

Reference unit

−

-2

31

to 2

31

−1

IL

18

Machine Coordinate System Latch
Position (LPOS)

Reference unit

−

-2

31

to 2

31

−1

IL

1A

Position Error (PERR)

Reference unit

−

-2

31

to 2

31

−1

IL

1C

Target Position Difference Monitor

Reference unit

−

-2

31

to 2

31

−1

IL

1E

Number of POSMAX Turns

Reference unit

−

-2

31

to 2

31

−1

IL

20

Speed Reference Output Monitor

pulse/s

−

-2

31

to 2

31

−1

IW

2C

Servo Driver Status

−

−

Bit setting

IW

2D

Servo Driver Alarm Code

−

−

-32768 to 32767

IW

2E

Servo Driver I/O Monitor

−

−

Bit setting

IW

2F

Servo Driver User Monitor Information

−

−

Bit setting

IL

30

Servo Driver User Monitor 2

−

−

-2

31

to 2

31

−1

IL

34

Servo Driver User Monitor 4

−

−

-2

31

to 2

31

−1

IW

36

Servo Driver User Constant No.

−

−

0 to 65535

IW

37

Supplementary Servo Driver User Con-
stant No.

−

−

0 to 65535

IL

38

Servo Driver User Constant Reading Data −

−

-2

31

to 2

31

−1

IL

3A

Supplementary Servo Driver User Con-
stant Reading Data

−

−

-2

31

to 2

31

−1

IW

3F

Motor Type

−

−

0, 1

IL

40

Feedback Speed

Depends on speed unit.

−

-2

31

to 2

31

−1

IL

42

Feedback Torque/Thrust

Depends on torque
unit.

−

-2

31

to 2

31

−1

IL

56

Fixed Parameter Monitor

−

−

-2

31

to 2

31

−1

IL

5E

Encoder Position When the Power is OFF
(Lower 2 words)

pulse

−

-2

31

to 2

31

−1

IL

60

Encoder Position When the Power is OFF
(Upper 2 words)

pulse

−

-2

31

to 2

31

−1

IL

62

Pulse Position When the Power is OFF
(Lower 2 words)

pulse

−

-2

31

to 2

31

−1

IL

64

Pulse Position When the Power is OFF
(Upper 2 words)

pulse

−

-2

31

to 2

31

−1

Advertising