11.2 Overtravel Function

11.2.1 Connections to

Σ-II/III/V Series SGDH, SGDS, or SGDV SERVOPACK

11-10

( 2 ) Parameter Settings

[ a ] Use/Not Use Overtravel Input Signals

The following parameters are used to enable and disable the overtravel input signals.

These parameters are disabled by executing a self-configuration command.

• SGDH SERVOPACKs

• SGDS and SGDV SERVOPACKs

[ b ] Selecting Motor Stopping Methods for Overtravel

When using the overtravel function has been enabled, the following parameters are used to set the methods for stopping
the motor. Select the methods for stopping when the P-OT or N-OT is input during motor running.

Parameter

Name

Set Value

Item

Default

Pn50A.3

P-OT Signal Mapping

2

(Recom-
mended)

Enables use of Positive Prohibit Input Signal
(P-OT). Forward rotation prohibited when
open, allowed for 0 V.

2

8

Disables the P-OT signal.

Pn50B.0

N-OT Signal Mapping

3

(Recom-
mended)

Enables use of Negative Prohibit Input Signal
(N-OT). Reverse rotation prohibited when
open, allowed for 0 V.

3

8

Disables the N-OT signal.

Parameter

Item

Pn50A.0

n.1

Enables use of Positive Prohibit Input Signal (P-OT).
Forward rotation prohibited when CN1-7 is open and allowed at 0 V. (Default setting)

n.8

Disables use of Positive Prohibit Input Signal (P-OT).
Constant forward rotation allowed. Equivalent to short circuit between the CN1-7 and
0 V (Control power supply for sequence signal input).

Pn50B.0

n.

2

Enables use of Negative Prohibit Input Signal (N-OT).
Reverse rotation prohibited when CN1-8 is open and allowed at 0 V. (Default setting)

n.

8

Disables use of Negative Prohibit Input Signal (N-OT).

Constant

reverse

rotation allowed.

Equivalent to short circuit between the CN1-8

and 0 V

(Control power supply for sequence signal input).

Parameter

Name

Set Value

Item

Default

Pn001.1

Overtravel Stop Mode

0

(Recom-
mended)

Stops the motor according to Pn001.0 setting
(dynamic brake or coasting) when overtravel is
detected.

0

1

Decelerates the motor to a stop by applying the
torque specified in Pn406 (Emergency Stop
Torque) when overtravel is detected, and then
sets it to zero clamp (servolock) mode.

2

Decelerates the motor to a stop by applying the
torque specified in Pn406 (Emergency Stop
Torque) when overtravel is detected, and then
sets it to coast (servo OFF) mode.

Pn001.0

Servo OFF Stop Mode

0

(Recom-
mended)

Stops the motor by applying dynamic brake (DB)
and then holds the DB.

0

1

Stops the motor by applying dynamic brake (DB)
and then releases the DB.

2

Makes the motor coast to a stop.
Current is not supplied to the motor and the
machine stops due to friction.