1.1 SVB Module Overview and Features

1.1.6 Synchronization between Modules

1-7

Overview

1.1.6 Synchronization between Modules

( 1 ) Overview

MP2200 and MP2300 Machine Controllers have a function that can synchronize hardware between the CPU and an
optional module. This function enables MECHATROLINK communications in synchronization with high-speed scans.
As a result, synchronization between a built-in SVB Module and an SVB-01 Module, or among multiple SVB-01 Mod-
ules, can be enabled.

When synchronized mode is used, the start of the high-speed scan and the various communication cycles are synchro-
nized. This means that commands from the high-speed scan will be sent at consistent points in communication cycle
processing and simplifies distribution processing for interpolation commands.

( 2 ) Conditions Under Which Synchronization Is Possible

The following table shows the combinations of high-speed scan times and MECHATROLINK communication cycles
that allow synchronization between modules in the synchronization mode.

( 3 ) Timing At Which Modules Are Synchronized

Modules are automatically synchronized when the power supply is turned OFF and ON again.

High-speed scan

4 ms

2 ms

1 ms

2 ms

Communication

cycle for SVB built

into the CPU

Communication

cycle for SVB-01

#1

Communication

cycle for SVB-01

#2

High-speed scan

(RTC: 0.5 ms)

MECHATROLINK Communication Cycle

0.5 ms

1 ms

1.5 ms

2 ms

1.0 ms

Yes

Yes

−

Yes

1.5 ms

Yes

−

Yes

−

2.0 ms

Yes

Yes

−

Yes

2.5 ms

Yes

−

−

−

3.0 ms

Yes

Yes

Yes

−

3.5 ms

Yes

−

−

−

4.0 ms

Yes

Yes

−

Yes

4.5 ms

Yes

−

Yes

−

5.0 ms

Yes

Yes

−

−

5.5 ms

Yes

−

−

−

6.0 ms

Yes

Yes

Yes

Yes

: