1.1 SVB Module Overview and Features

1.1.6 Synchronization between Modules

1-7

Overview

1.1.6 Synchronization between Modules

( 1 ) Overview

MP2200 and MP2300 Machine Controllers have a function that can synchronize hardware between the CPU and an
optional module. This function enables MECHATROLINK communications in synchronization with high-speed scans.
As a result, synchronization between a built-in SVB Module and an SVB-01 Module, or among multiple SVB-01 Mod-
ules, can be enabled.

When synchronized mode is used, the start of the high-speed scan and the various communication cycles are synchro-
nized. This means that commands from the high-speed scan will be sent at consistent points in communication cycle
processing and simplifies distribution processing for interpolation commands.

( 2 ) Conditions Under Which Synchronization Is Possible

The following table shows the combinations of high-speed scan times and MECHATROLINK communication cycles
that allow synchronization between modules in the synchronization mode.

( 3 ) Timing At Which Modules Are Synchronized

Modules are automatically synchronized when the power supply is turned OFF and ON again.

High-speed scan

4 ms

2 ms

1 ms

2 ms

Communication

cycle for SVB built

into the CPU

Communication

cycle for SVB-01

#1

Communication

cycle for SVB-01

#2

High-speed scan

(RTC: 0.5 ms)

MECHATROLINK Communication Cycle

0.5 ms

1 ms

1.5 ms

2 ms

1.0 ms

Yes

Yes

Yes

1.5 ms

Yes

Yes

2.0 ms

Yes

Yes

Yes

2.5 ms

Yes

3.0 ms

Yes

Yes

Yes

3.5 ms

Yes

4.0 ms

Yes

Yes

Yes

4.5 ms

Yes

Yes

5.0 ms

Yes

Yes

5.5 ms

Yes

6.0 ms

Yes

Yes

Yes

Yes

: