11.6 Parameters That Are Automatically Updated

11.6.5 Parameters Updated during Self-configuration

11-25

Utility Functions

( 2 ) SERVOPACK Parameters

The SERVOPACK parameters are written to SERVOPACK EEPROM or RAM during self-configuration as shown
below. Care must therefore be taken because the SERVOPACK parameters will be overwritten when self-configuration
is executed.

These settings, however, are not written to the set values for the SERVOPACK parameters saved in the Machine
Controller.

[ a ] SERVOPACK Parameters (1)

* 1. The assigned SERVOPACK terminal differs with the model of SERVOPACK used as shown in the following table.

* 2. Allocated for the TFF/TLIM function of the position control command.
* 3. Uses Pn834 to Pn83E.

The above processing is not performed when the axis has been set.
The above set values are written to the SERVOPACK’s EEPROM.

MP2000 Series Machine Controller

SERVOPACK

SERVOPACK Parameters

SGD-N,

SGDB-N

SGDH +

NS100

SGDH +

NS115

SGDS

SGDV

Name

Setting

P-OT Signal Mapping

Disable

Cn-0001 Bit 2

Pn50A.3

N-OT Signal Mapping

Disable

Cn-0001 Bit 3

Pn50B.0

SERVOPACK Software Limit Func-
tion (Positive)

Disable

Cn-0014 Bit 2

Pn801.0

SERVOPACK Software Limit Func-
tion (Negative)

Disable

Cn-0014 Bit 3

SERVOPACK Electronic Gear Ratio
(Numerator)

1

Cn-0024

Pn202

Pn20E

SERVOPACK Electronic Gear Ratio
(Denominator)

1

Cn-0025

Pn203

Pn210

Normal Autotuning Switches

Disable

Pn110

/DEC Signal Mapping

*1

Pn511.0

/EXT1 Signal Mapping

*1

Pn511.1

/EXT2 Signal Mapping

*1

Pn511.2

/EXT3 Signal Mapping

*1

Pn511.3

Velocity Control Option

Use T-REF as the
external torque
limit input.

Pn002.0

Torque Control Option

Use V-REF as
the external
speed limit input.

Pn002.1

Forward Latching Allowable Area

Pn820 value

Pn822

Command Data Allocation

1

Pn81F.1

*2

Linear Accel/Decel Constant
Selection

1

Pn833.0

*3

Signal

Name

SERVOPACK Model

Setting

Signal

Name

SERVOPACK Model

Setting

/DEC

SGDS

CN1-9

/EXT2

SGDS

CN1-11

SGDH

CN1-41

SGDH

CN1-45

SGDV-

J1

CN1-41

SGDV-

J1

CN1-45

SGDV-

E1

N/A

SGDV-

E1

N/A

Other SGDV models

CN1-9

Other SGDV models

CN1-11

/EXT1

SGDS

CN1-10

/EXT3

SGDS

CN1-12

SGDH

CN1-44

SGDH

CN1-46

SGDV-

J1

CN1-44

SGDV-

J1

CN1-46

SGDV-

E1

N/A

SGDV-

E1

N/A

Other SGDV models

CN1-10

Other SGDV models

CN1-12

Advertising