7 switching from step – Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual
Page 295

7.2 Motions After Switching Motion Commands
7.2.7 Switching from STEP
7-25
Switching Commands during Execution
7.2.7 Switching from STEP
Switched From
Switched To
Operation
STEP
NOP
STEP will switch to NOP when the axis stops after deceleration.
POSING
STEP will immediately switch to POSING, and the moving amount stored in the accelera-
tion/deceleration filter will be maintained.
The value of the Position Reference Setting (OL
1C) when the motion command is
switched will be as follows.
<In Incremental Addition Mode (OW
09, bit 5 = 0)>
Incremental value = Target position
− IL
14 (DPOS)
OL
1C = OL
1C+ Incremental value
<In Absolute Mode (OW
09, bit 5 = 1)>
OL
1C = Target position
EX_POSING
STEP will immediately switch to EX_POSING, and the moving amount stored in the
acceleration/deceleration filter will be maintained.
The value of the Position Reference Setting (OL
1C) when the motion command is
switched will be as follows.
<In Incremental Addition Mode (OW
09, bit 5 = 0)>
Incremental value = Target position
− IL
14 (DPOS)
OL
1C = OL
1C+ Incremental value
<In Absolute Mode (OW
09, bit 5 = 1)>
OL
1C = Target position
STEP
STEP
NOP
STEP
NOP
Motion command
Motion command
response
STEP
STEP
POSING
STEP
POSING
The speed will smoothly change.
(The speed at the time the motion command
is switched will increase/decrease until it
reaches the target speed of POSING.)
The acceleration/deceleration filter will
remain valid.
POSING
Motion command
Motion command
response
STEP
STEP
EX_POSING
STEP
EX_POSING
The speed will smoothly change.
(The speed at the time the motion com-
mand is switched will increase/decrease
until it reaches the target speed of
EX_POSING.)
The acceleration/deceleration filter will
remain valid.
EX_POSING
Motion command
Motion command
response