7 switching from step – Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual

Page 295

Advertising
background image

7.2 Motions After Switching Motion Commands

7.2.7 Switching from STEP

7-25

Switching Commands during Execution

7.2.7 Switching from STEP

Switched From

Switched To

Operation

STEP

NOP

STEP will switch to NOP when the axis stops after deceleration.

POSING

STEP will immediately switch to POSING, and the moving amount stored in the accelera-
tion/deceleration filter will be maintained.

The value of the Position Reference Setting (OL

1C) when the motion command is

switched will be as follows.

<In Incremental Addition Mode (OW

09, bit 5 = 0)>

Incremental value = Target position

− IL

14 (DPOS)

OL

1C = OL

1C+ Incremental value

<In Absolute Mode (OW

09, bit 5 = 1)>

OL

1C = Target position

EX_POSING

STEP will immediately switch to EX_POSING, and the moving amount stored in the
acceleration/deceleration filter will be maintained.

The value of the Position Reference Setting (OL

1C) when the motion command is

switched will be as follows.

<In Incremental Addition Mode (OW

09, bit 5 = 0)>

Incremental value = Target position

− IL

14 (DPOS)

OL

1C = OL

1C+ Incremental value

<In Absolute Mode (OW

09, bit 5 = 1)>

OL

1C = Target position

STEP

STEP

NOP

STEP

NOP

Motion command

Motion command

response

STEP

STEP

POSING

STEP

POSING

The speed will smoothly change.

(The speed at the time the motion command

is switched will increase/decrease until it

reaches the target speed of POSING.)

The acceleration/deceleration filter will

remain valid.

POSING

Motion command
Motion command

response

STEP

STEP

EX_POSING

STEP

EX_POSING

The speed will smoothly change.

(The speed at the time the motion com-

mand is switched will increase/decrease

until it reaches the target speed of

EX_POSING.)

The acceleration/deceleration filter will

remain valid.

EX_POSING

Motion command
Motion command

response

Advertising