4 ) timing charts – Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual

Page 230

Advertising
background image

6.2 Motion Command Details

6.2.16 Read User Constant (PRM_RD)

6-69

Motion Commands

[ b ] Monitoring Parameters

( 4 ) Timing Charts

[ a ] Normal End

[ b ] Error End

Parameter

Name

Monitor Contents

IL

02

Warning

Stores the most current warning.

IL

04

Alarm

Stores the most current alarm.

IW

08

Motion Command
Response Code

Indicates the motion command that is being executed.
The response code will be 17 during PRM_RD command execution.

IW

09

Bit 0

Command Execution Flag

Turns ON during PRM_RD command execution and turns OFF when execu-
tion has been completed.

IW

09

Bit 1

Command Hold Completed

Always OFF for PRM_RD command.

IW

09

Bit 3

Command Error Completed
Status

Turns ON if an error occurs during PRM_RD command execution. Turns OFF
when another command is executed.

IW

09

Bit 8

Command Execution
Completed

Turns ON when PRM_RD command execution has been completed.

IW

36

Servo Driver User Constant
No.

Stores the number of the SERVOPACK parameter that was read.

IL

38

Servo Driver User Constant
Reading Data

Stores the data of the SERVOPACK parameter that was read.

OW

08 = 17 (PRM-RD)

IW

08 = 17 (PRM-RD)

IW

09, bit 0 (BUSY)

IW

09, bit 8 (COMPLETE)

IW

09, bit 3 (FAIL)

Undefined length

of time

OW

08 = 17 (PRM-RD)

IW

08 = 17 (PRM-RD)

IW

09, bit 0 (BUSY)

IW

09, bit 8 (COMPLETE)

IW

09, bit 3 (FAIL)

Undefined length

of time