( 3 ) Related Parameters

[ a ] Setting Parameters

[ b ] Monitoring Parameters

Parameter

Name

Setting

OW

00

Bit 0

Servo ON

Turn the power to the Servomotor ON and OFF.
1: Power ON to Servomotor; 0: Power OFF to Servomotor
Turn OFF the power before setting the Motion Command (OW

08) to 22.

OW

08

Motion Command

Starts resetting the absolute encoder when this parameter is set to 22.
Even if this parameter is set to 0 during command processing, it will be ignored and
execution will be continued.

OW

09

Bit 0

Holds a Command

This parameter is ignored for the ABS_RST command.

OW

09

Bit 1

Interrupt a Command

This parameter is ignored for the ABS_RST command.

Parameter

Name

Monitor Contents

IW

00

Bit 0

Motion Controller
Operation Ready

Indicates the communication status between the Machine Controller and SERVOPACK.
1: Communication synchronized, 0: Communication disconnected

IW

00

Bit 1

Servo ON

Indicates the Servo ON status.
1: Power supplied to Servomotor, 0: Power not supplied to Servomotor

IL

02

Warning

Stores the most current warning.

IL

04

Alarm

Stores the most current alarm.

IW

08

Motion Command
Response Code

Indicates the motion command that is being executed.
The response code will be 22 during ABS_RST command execution.

IW

09

Bit 0

Command Execution
Flag

Turns ON during ABS_RST command execution and turns OFF when execution has
been completed.

IW

09

Bit 1

Command Hold
Completed

Always OFF for the ABS_RST command.

IW

09

Bit 3

Command Error
Completed Status

Turns ON if an error, such as a communication error, occurs during ABS_RST com-
mand execution.
Command execution will be canceled.

IW

09

Bit 7

Absolute Encoder
Reset Completed

Turns ON when resetting the absolute encoder has been completed.

IW

09

Bit 8

Command Execution
Completed

Turns ON when ABS_RST command execution has been completed.