4.3 Motion Parameter Lists

4.3.2 Setting Parameter List

4-9

Motion Parameters

OW

03 Function Setting 1

Bits 0 to 3: Speed Unit Selection
0: Reference unit/s
1: 10

n

reference unit/min

2: Percentage of rated speed (1 = 0.01%)
3: Percentage of rated speed (1 = 0.0001%)

Yes

Yes

4.4.2 ( 4 )

Bits 4 to 7: Acceleration/Deceleration Degree Unit Selection
0: Reference unit/s

2

1: ms

Yes

Yes

Bits 8 to B: Filter Type Selection
0: None
1: Exponential acceleration/deceleration filter
2: Moving average filter

Yes

Yes

Bits C to F: Torque Unit Selection
0: Percentage of rated toque (1 = 0.01%)
1: Percentage of rated toque (1 = 0.0001%)

Yes

Yes

OW

04 Function Setting 2

Bits 0 to 3: Latch Detection Signal Selection

4.4.2 ( 5 )

0: -

1: -

2: Phase-C pulse

Yes

3: /EXT1

Yes

4: /EXT2

Yes

5: /EXT3

Yes

Bits 4 to 7: External Positioning Signal Setting

0:

1:

2: Phase-C pulse

Yes

3: /EXT1

Yes

4: /EXT2

Yes

5: /EXT3

Yes

Bits 8 to B: Reserved for system use.

Bits C to F: Bank Selector

Yes

OW

05 Function Setting 3

Bit 1: Phase Reference Creation Calculation Disable (0: Enabled/
1: Disabled)

Yes

4.4.2 ( 6 )

Bits 2 to A: Reserved for system use.

Bit B: Zero Point Return Input Signal (0: OFF/1: ON)

Yes

Bits C to F: Reserved for system use.

OW

06

to

OW

07

Reserved for system use.

(cont’d)

Register No.

Name

Contents

SVB SVR Reference