2.1 LED Indicators and Switch Settings
2.1.4 Switch Settings
2-4
2.1.4 Switch Settings
Both the DIP switch and rotary switches set the operating conditions for the SVB-01 Module. Use the default settings
when using the Module in Master Mode.
( 1 ) DIP Switch
SIZE and SPD are valid only in Slave Mode. They will be ignored in Master Mode.
Setting Example
Name
Status
Operating Mode
Default Setting
Details
-
ON
Reserved.
OFF
Keep turned OFF.
OFF
Reserved.
M/S
ON
Slave Mode
OFF
Select Master or Slave Mode.
OFF
Master Mode
SIZE
ON
17 bytes
OFF
Select the number of send bytes.
Valid only in Slave Mode.
OFF
32 bytes
SPD
ON
4 Mbps
OFF
Select the baud rate.
Valid only in Slave Mode.
OFF
10 Mbps
Communication
Interface
Link
Communication
Switch Settings
MECHATROLINK-I
17-byte
MECHATROLINK-II
17-byte
32-byte
OFF
ON
SPD
SIZE
M/S
OFF
ON
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
OFF