18 alarm monitor (alm_mon), 1 ) executing/operating procedure, 2 ) holding and aborting – Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual

Page 233: 3 ) related parameters

Advertising
background image

6.2 Motion Command Details

6.2.18 Alarm Monitor (ALM_MON)

6-72

6.2.18 Alarm Monitor (ALM_MON)

The ALM_MON command reads the alarm or warning that has occurred in the SERVOPACK and stores it in Servo
Driver Alarm Code (monitoring parameter IW

2D). 3-digit alarm codes, such as SGDS or SGDV SERVOPACK

alarm codes, can also be read out by using this command.

( 1 ) Executing/Operating Procedure

1.

Check to see if all the following conditions are satisfied.

2.

Set OW

08 to 19 to execute the ALM_MON motion command.

The ALM_MON command will read the alarm or warning that has occurred in the SERVOPACK and store it in
Servo Driver Alarm Code (monitoring parameter IW

2D).

IW

08 will be 19 during command execution.

IW

09, bit 0 will turn ON during the command processing and will turn OFF when the command processing

has been completed.

3.

Set OW

08 to 0 to execute the NOP motion command and then complete the monitoring operation.

( 2 ) Holding and Aborting

The Holds a Command bit (OW

09, bit 0) and the Interrupt a Command bit (OW

09, bit 1) cannot be used.

( 3 ) Related Parameters

[ a ] Setting Parameters

[ b ] Monitoring Parameters

No.

Execution Conditions

Confirmation Method

1

Motion command execution has been completed.

IW

08 is 0 and IW

09, bit 0 is OFF.

Parameter

Name

Setting

OW

08

Motion Command

Alarms are monitored when this parameter is set to 19.

OW

09

Bit 0

Holds a Command

This parameter is ignored for ALM_MON command.

OW

09

Bit 1

Interrupt a Command

This parameter is ignored for ALM_MON command.

OW

4F

Servo Driver Alarm
Monitor No.

When several alarms and warnings occur at the same time, set the number of the alarm
or warning to be monitored.

Parameter

Name

Monitor Contents

IL

02

Warning

Stores the most current warning.

IL

04

Alarm

Stores the most current alarm.

IW

08

Motion Command
Response Code

Indicates the motion command that is being executed.
The response code will be 19 during ALM_MON command execution.

IW

09

Bit 0

Command Execution
Flag

Turns ON during ALM_MON command execution and turns OFF when execution has
been completed.

IW

09

Bit 1

Command Hold
Completed

Always OFF for ALM_MON command.

IW

09

Bit 3

Command Error
Completed Status

Turns ON if an error occurs during ALM_MON command execution.
Turns OFF when another command is executed.

IW

09

Bit 8

Command Execution
Completed

Turns ON when ALM_MON command execution has been completed.

IW

2D

Servo Driver Alarm
Code

Stores the SERVOPACK alarm or warning code that was read.

Advertising