7.2 Motions After Switching Motion Commands

7.2.6 Switching from FEED

7-23

Switching Commands during Execution

FEED

INTERPOLATE

FEED will switch to INTERPOLATE when the axis stops after deceleration.

<Change in Position Reference Setting (OL

1C) during Deceleration>

• In Incremental Addition Mode (OW

09, bit 5 = 0)

Any change in the Position Reference Setting (OL

1C) will be ignored.

• In Absolute Mode (OW

09, bit 5 = 1)

The change in the Position Reference Setting (OL

1C) will be output at as soon as at

the timing of the first high-speed scan after INTERPOLATE execution starts.

Do not change the Position Reference Setting during deceleration unless it is
absolutely necessary.

ENDOF_INTER

POLATE

Same as INTERPOLATE

LATCH

Same as INTERPOLATE

FEED

FEED operation will continue.

STEP

FEED will switch to STEP when the axis stops after deceleration.

ZSET

FEED will immediately switch to ZSET, and the FEED operation will continue.

In actual operation, set the zero point by executing ZSET in the positioning
completed status.

Switched From

Switched To

Operation

FEED

Cancelled FEED
operation

FEED

INTERPOLATE

FEED

INTERPOLATE

INTERPOLATE

Motion command

Motion command

response

Cancelled FEED
operation

FEED

FEED

STEP

FEED

STEP

STEP

Motion command

Motion command

response

FEED

FEED operation will
continue.

FEED

ZSET

FEED

ZSET

Motion command

Motion command
response