8.4 Speed Control

8.4.1 Motion Parameters for Speed Control

8-21

Control Block Diagrams

( 2 ) Setting Parameters

No.

Name

Setting Unit

Default

Value

Setting Range

OW

00

RUN Command Setting

0000h

Bit setting

OW

01

Mode Setting 1

0000h

Bit setting

OW

02

Mode Setting 2

0000h

Bit setting

OW

03

Function Setting 1

0011h

Bit setting

OW

04

Function Setting 2

0033h

Bit setting

OW

05

Function Setting 3

0000h

Bit setting

OW

08

Motion Command

0

0 to 39

OW

09

Motion Command Control Flag

0000h

Bit setting

OW

0A

Motion Subcommand

0

0 to 65535

OL

0C

Torque/Thrust Reference Setting

Depends on torque
unit.

0

-2

31

to 2

31

−1

OW

0E

Speed Limit Setting at the Torque/Thrust Refer-
ence

0.01%

15000

-32768 to 32767

OL

10

Speed Reference Setting

Depends on speed
unit.

3000

-2

31

to 2

31

−1

OL

14

Positive Side Limiting Torque/Thrust Setting at
the Speed Reference

Depends on torque
unit.

30000

-2

31

to 2

31

−1

OL

16

Secondly Speed Compensation

Depends on speed
unit.

0

-2

31

to 2

31

−1

OW

18

Override

0.01%

10000

0 to 32767

OL

1C

Position Reference Setting

Reference unit

0

-2

31

to 2

31

−1

OL

1E

Width of Positioning Completion

Reference unit

100

0 to 65535

OL

20

NEAR Signal Output Width

Reference unit

0

0 to 65535

OL

22

Error Count Alarm Detection

Reference unit

2

31

−1

0 to 2

31

−1

OW

26

Positioning Completion Check Time

ms

0

0 to 65535

OL

28

Phase Correction Setting

Reference unit

0

-2

31

to 2

31

−1

OL

2A

Latch Zone Lower Limit Setting (for External Po-
sitioning)

Reference unit

-2

31

-2

31

to 2

31

−1

OL

2C

Latch Zone Upper Limit Setting (for External Po-
sitioning)

Reference unit

2

31

−1

-2

31

to 2

31

−1

OW

2E

Position Loop Gain

0.1/s

300

0 to 32767

OW

2F

Speed Loop Gain

Hz

40

1 to 2000

OW

30

Speed Feed Forward Amends

0.01%

0

0 to 32767

OW

31

Speed Amends

0.01%

0

-32768 to 32767

OW

32

Position Integration Time Constant

ms

0

0 to 32767

OW

34

Speed Integration Time Constant

0.01 ms

2000

15 to 65535

OL

36

Straight Line Acceleration/Acceleration Time
Constant

Depends on acceler-
ation/deceleration
speed unit.

0

0 to 2

31

−1

OL

38

Straight Line Deceleration/Deceleration Time
Constant

Depends on acceler-
ation/deceleration
speed unit.

0

0 to 2

31

−1

OW

3A

Filter Time Constant

0.1 ms

0

0 to 65535

OW

3C

Zero Point Return Method

0

0 to 19

OW

3D

Width of Starting Point Position Output

Reference unit

100

0 to 65535

OL

3E

Approach Speed

Depends on speed
unit.

1000

-2

31

to 2

31

−1

OL

40

Creep Rate

Depends on speed
unit.

500

-2

31

to 2

31

−1

OL

42

Zero Point Return Travel Distance

Reference unit

0

-2

31

to 2

31

−1

OL

44

STEP Travel Distance

Reference unit

1000

0 to 2

31

−1

OL

46

External Positioning Final Travel Distance

Reference unit

0

-2

31

to 2

31

−1

OL

48

Zero Point Position in Machine Coordinate Sys-
tem Offset

Reference unit

0

-2

31

to 2

31

−1

OL

4A

Work Coordinate System Offset

Reference unit

0

-2

31

to 2

31

−1

Advertising