4 ) system service execution status, 5 ) alarm counter and alarm clear – Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual
Page 458

12.2 Troubleshooting System Errors
12.2.4 System Register Configuration and Error Status
12-15
Troubleshooting
( 4 ) System Service Execution Status
[ a ] Data Trace Execution Status
[ b ] Latest Data Trace Record Numbers
( 5 ) Alarm Counter and Alarm Clear
Name
Register No.
Remarks
Reserved by the system
SW00090 to
SW00097
Existence Of Data Trace Definition
SW00098
Bits 0 to 3 = Group 1 to 4
Definition exists = 1, No definition = 0
Data Trace Execution Status
SW00099
Bits 0 to 3 = Group 1 to 4
Trace stopped = 1, Trace executing = 0
Name
Register No.
Remarks
Data Trace Group 1
SW00100
Latest record number
Data Trace Group 2
SW00101
Latest record number
Data Trace Group 3
SW00102
Latest record number
Data Trace Group 4
SW00103
Latest record number
Name
Register No.
Remarks
Number of Alarm Occurrences
SW00190
Number of alarm occurrences
Number of Alarm Histories
SW00191
Number of alarm histories
Alarm Clear
SW00192
1: Clear alarms.
2: Clear the number of alarm occurrences and alarm
histories.