6.2 Motion Command Details

6.2.17 Write User Constant (PRM_WR)

6-70

6.2.17 Write User Constant (PRM_WR)

The PRM_WR command writes the setting value the relevant SERVOPACK parameter using the specified SERVO-
PACK parameter number, parameter size, and setting data.

( 1 ) Executing/Operating Procedure

1.

Check to see if all the following conditions are satisfied.

2.

Set OW

08 to 18 to execute the PRM_WR motion command.

The SERVOPACK parameter will be written.
IW

08 will be 18 during command execution.

IW

09, bit 0 will turn ON during the command processing and will turn OFF when the command processing

has been completed.

3.

Set OW

08 to 0 to execute the NOP motion command and then complete the writing operation.

( 2 ) Holding and Aborting

The Holds a Command bit (OW

09, bit 0) and the Interrupt a Command bit (OW

09, bit 1) cannot be used.

( 3 ) Related Parameters

[ a ] Setting Parameters

[ b ] Monitoring Parameters

No.

Execution Conditions

Confirmation Method

1

There are no alarms.

Both IL

02 and IL

04 are 0.

2

Motion command execution has been completed.

IW

08 is 0 and IW

09, bit 0 is OFF.

Parameter

Name

Setting

OW

08

Motion Command

The SERVOPACK parameter is written when this parameter is set to 18.

OW

09

Bit 0

Holds a Command

This parameter is ignored for PRM_WR command.

OW

09

Bit 1

Interrupt a Command

This parameter is ignored for PRM_WR command.

OW

50

Servo Driver User
Constant No.

Set the number of the SERVOPACK parameter to be written.

OW

51

Servo Driver User
Constant Size

Set the size of the SERVOPACK parameter to be written.
Set the size as the number of words.
Example: For 4 bytes, set “2.”

OL

52

Servo Driver User
Constant Set Point

Set the data to be set to the SERVOPACK parameter to be written.

Parameter

Name

Monitor Contents

IL

02

Warning

Stores the most current warning.

IL

04

Alarm

Stores the most current alarm.

IW

08

Motion Command
Response Code

Indicates the motion command that is being executed.
The response code will be 18 during PRM_WR command execution.

IW

09

Bit 0

Command Execution
Flag

Turns ON during PRM_WR command execution and turns OFF when execution has
been completed.

IW

09

Bit 1

Command Hold
Completed

Always OFF for PRM_WR command.

IW

09

Bit 3

Command Error
Completed Status

Turns ON if an error occurs during PRM_WR command execution.
Turns OFF when another command is executed.

IW

09

Bit 8

Command Execution
Completed

Turns ON when PRM_WR command execution has been completed.