3.4 Self-configuration and Definition Files
3.4.4 Current Value and Setting Data in SVB
3-30
( 5 ) Copying Current Values to Set Values (Input Data) in the SERVOPACK Tab
The data flow for SERVOPACK parameters is as follows when selecting Edit - Copy Current Value from the SERVO-
PACK Tab in the SVB Definition Window on the MPE720:
• The MPE720 copies the values currently displayed in Current to Input Data on the SERVOPACK Tab and dis-
plays.
indicates data has been written.
The following figure shows a display example after having selected Edit - Copy Current Value on the SERVOPACK
Tab in the SVB Definition Window. The values in Current are copied to Input Data.
MECHATROLINK
RAM
EEP
-ROM
SRAM
SDRAM
Machine Controller
SERVOPACK
SERVOPACK
Control
Software
System
Software
Parameters
SERVOPACK Parameters
(All Axes)
Flash
Memory
Input
Data
MPE720 㧔online㧕
HDD in personal computer
Display
Current
Value
Input
Data
Before copying
After copying