5 inverter alarm and warning codes, 1 inverter alarms – Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual

Page 411

Advertising
background image

10.5 Inverter Alarm and Warning Codes

10.5.1 Inverter Alarms

10-47

Settings for Connecting Inverters

10.5 Inverter Alarm and Warning Codes

Errors are classified by the following four types, according to where the error occurred and the error contents.

* SI-T refers to the MECHATROLINK option board.

When more than one error is detected at one time, the SI-T will report the alarms in order from the smallest alarm
code number.
When another error is detected while another is being detected, the alarm code will not be refreshed.
When more than one minor failure (warning) is detected at one time, the SI-T will report alarms in order from the
smallest warning code number.

Inverter alarms and warnings are described below.

10.5.1 Inverter Alarms

Error Type

Contents

Place the Error

Occurred

Alarm

Inverter Alarm

Serious failure that can damage the inverter and machine

Inverter

Communication Alarm

MECHATROLINK communication failure

SI-T

*

Warning

Inverter Warning

Incorrect operation or minor failure that will not likely
result in a serious situation.

Inverter

Communication Warning

MECHATROLINK communication error warning

SI-T

*

Alarm Code

(IW

30)

Status (IW

10)

Digital

Operator

Display

Contents

V

ar

ispeed G7

V

arispee

d F7

VSmini

V7

WARNG

ALM

01H

ON

PUF

Blown fuse

×

02H

ON

UV1

Main circuit undervoltage

03H

ON

UV2

Control circuit undervoltage

04H

ON

UV3

MC failure

×

06H

ON

GF

Ground fault

*1

07H

ON

OC

Overcurrent

08H

ON

OV

Overvoltage

09H

ON

OH

Inverter overheat

0AH

ON

OH1

Inverter overheat

×

0BH

ON

OL1

Motor overload

0CH

ON

OL2

Inverter overload

0DH

ON

OL3

Overtorque 1

0EH

ON

OL4

Overtorque 2

×

0FH

ON

RR

Control transistor fault

×

10H

ON

RH

Braking resistor overheat

*1

11H

ON

EF3

External fault 3

12H

ON

EF4

External fault 4

13H

ON

EF5

External fault 5

14H

ON

EF6

External fault 6

15H

ON

EF7

External fault 7

16H

ON

EF8

External fault 8

×

18H

ON

OS

Excessive Speed

×

19H

ON

DEV

Excessive speed deviation

×

1AH

ON

PGO

PG disconnected

×

1BH

ON

PF

Input open phase

1CH

ON

LF

Output open phase

1DH

ON

OH3

Motor overheat 1

×

1EH

ON

OPR

Operator disconnected

1FH

ON

ERR

EEPROM writing error

×

Advertising