10.5 Inverter Alarm and Warning Codes

10.5.1 Inverter Alarms

10-47

Settings for Connecting Inverters

10.5 Inverter Alarm and Warning Codes

Errors are classified by the following four types, according to where the error occurred and the error contents.

* SI-T refers to the MECHATROLINK option board.

When more than one error is detected at one time, the SI-T will report the alarms in order from the smallest alarm
code number.
When another error is detected while another is being detected, the alarm code will not be refreshed.
When more than one minor failure (warning) is detected at one time, the SI-T will report alarms in order from the
smallest warning code number.

Inverter alarms and warnings are described below.

10.5.1 Inverter Alarms

Error Type

Contents

Place the Error

Occurred

Alarm

Inverter Alarm

Serious failure that can damage the inverter and machine

Inverter

Communication Alarm

MECHATROLINK communication failure

SI-T

*

Warning

Inverter Warning

Incorrect operation or minor failure that will not likely
result in a serious situation.

Inverter

Communication Warning

MECHATROLINK communication error warning

SI-T

*

Alarm Code

(IW

30)

Status (IW

10)

Digital

Operator

Display

Contents

V

ar

ispeed G7

V

arispee

d F7

VSmini

V7

WARNG

ALM

01H

−

ON

PUF

Blown fuse

×

02H

−

ON

UV1

Main circuit undervoltage

03H

−

ON

UV2

Control circuit undervoltage

04H

−

ON

UV3

MC failure

×

06H

−

ON

GF

Ground fault

*1

07H

−

ON

OC

Overcurrent

08H

−

ON

OV

Overvoltage

09H

−

ON

OH

Inverter overheat

0AH

−

ON

OH1

Inverter overheat

×

0BH

−

ON

OL1

Motor overload

0CH

−

ON

OL2

Inverter overload

0DH

−

ON

OL3

Overtorque 1

0EH

−

ON

OL4

Overtorque 2

×

0FH

−

ON

RR

Control transistor fault

×

10H

−

ON

RH

Braking resistor overheat

*1

11H

−

ON

EF3

External fault 3

12H

−

ON

EF4

External fault 4

13H

−

ON

EF5

External fault 5

14H

−

ON

EF6

External fault 6

15H

−

ON

EF7

External fault 7

16H

−

ON

EF8

External fault 8

×

18H

−

ON

OS

Excessive Speed

×

19H

−

ON

DEV

Excessive speed deviation

×

1AH

−

ON

PGO

PG disconnected

×

1BH

−

ON

PF

Input open phase

1CH

−

ON

LF

Output open phase

1DH

−

ON

OH3

Motor overheat 1

×

1EH

−

ON

OPR

Operator disconnected

1FH

−

ON

ERR

EEPROM writing error

×

Advertising