12.4 List of Causes for Command Error Occurrence

12-30

13

Change Filter Type
(CHG_FILTER)

An alarm is occurring.

Asynchronous communication status

A: Servo Driver Synchronization
Communications Error

Executed before distribution has been completed
(DEN = OFF).

A: Filter Time Constant Change Error

The selected filter type is out of the setting range.

W: Set Parameter Error

14,
15,

and

16

Change Speed Loop Gain
(KVS)
Change Position Loop
Gain
(KPS)
Change Feed Forward
(KFS)

An alarm is occurring.

Asynchronous communication status

A: Servo Driver Synchronization
Communications Error

SERVOPACK parameter writing was not com-
pleted within the specified time.

A: Servo Driver Command Timeout
Error

Warning A.94 or A.95 occurred in the SERVO-
PACK.

W: Servo Driver Error

17

and

18

Read User Constant
(PRM_RD)
Write User Constant
(PRM_WR)

An alarm is occurring.

Asynchronized communication status

A: Servo Driver Synchronization
Communications Error

SERVOPACK parameter reading was not com-
pleted within the specified time.

A: Servo Driver Command Timeout
Error

Warning A.94 or A.95 occurred in the SERVO-
PACK.

W: Servo Driver Error

SERVOPACK parameter number or size is outside
the setting range.

W: Set Parameter Error

19

and

20

Alarm Monitor
(ALM_MON)
Alarm History Monitor
(ALM_HIST)

The command to the SERVOPACK was not com-
pleted within the specified time.

A: Servo Driver Command Timeout
Error

Servo driver alarm monitor number is outside set-
ting range.

W: Set Parameter Error

21

Clear Alarm History
(ALMHIST_CLR)

The command to the SERVOPACK was not com-
pleted within the specified time.

A: Servo Driver Command Timeout
Error

22

Absolute Encoder Reset
(ABS_RST)

This command was used for

Σ-I SERVOPACK.

Executed while servo was ON.

Asynchronous communication status

A: Servo Driver Synchronization
Communications Error

The command to the SERVOPACK was not com-
pleted within the specified time.

A: Servo Driver Command Timeout
Error

23

Speed Reference
(VELO)

Commanded while connected to MECHA-
TROLINK-I.

An alarm is occurring.

Asynchronous communication status

A: Servo Driver Synchronization
Communications Error

24

Torque/Thrust Reference
(TRQ)

Commanded while connected to MECHA-
TROLINK-I.

An alarm is occurring

Asynchronous communication status

A: Servo Driver Synchronization
Communications Error

25

Phase Reference
(PHASE)

The axis is ABS infinite length, and the zero point
return (setting) is not completed.

A: Zero Point Unsetting

In servo OFF status

A: Servo OFF

An alarm is occurring.

Asynchronous communication status

A: Servo Driver Synchronization
Communications Error

(cont’d)

Motion Command Code

Cause of Command Error Occurrence

Warning (W:) and Alarm (A:) That

Occur at Command Error Occurrence