11.6 Parameters That Are Automatically Updated

11.6.1 Parameters Updated when a MECHATROLINK Connection Is Established (1) (User Constants Self-writing Function Enabled)

11-21

Utility Functions

11.6 Parameters That Are Automatically Updated

Some of the parameters stored in SERVOPACK RAM may be overwritten automatically under certain conditions or as
a result of self-configuration. This includes MP2000-series Machine Controller setting parameters and fixed parame-
ters, as well as fixed value SERVOPACK parameters. Some SERVOPACK parameters are also written to setting
parameters automatically during self-configuration. The parameters that are updated automatically under specific con-
ditions are listed in the following tables.

Refer to Chapter 4 Motion Parameters for details on Machine Controller parameters. Refer to your SERVOPACK
manual for details on SERVOPACK parameters.

11.6.1 Parameters Updated when a MECHATROLINK Connection Is Established (1)

(User Constants Self-writing Function Enabled)

The Machine Controller parameter settings in the left table below are automatically written to the SERVOPACK
parameters given in the right table below when a connection is established between the Machine Controller and the
SERVOPACK. This occurs after power is turned ON or alarms are cleared following a communication interruption.
The parameters are written only when User Constants Self-writing Function is enabled when bit A of fixed parameter 1
in the Machine Controller is set to 0.

* 1. Updated when using MECHATROLINK-II (10 Mbps, 32 bytes).
* 2. When Pn833.0 is set to 0, Pn80B will be updated. When Pn833.0 is set to 1, Pn836 will be updated.
* 3. When Pn833.0 is set to 0, Pn80E will be updated. When Pn833.0 is set to 1, Pn83C will be updated.

MP2000-Series Machine Controller

SERVOPACK Parameter

Remarks

SGD-N, SGDB-N NS100

NS115

SGDS

SGDV

Setting p

ara

meters

Width of Positioning
Completion

OL

1E

Pn500

*1

Pn522

*1

* Settings are written only

when using a MECHA-
TROLINK-II operating at 10
Mbps in 32-byte mode.

Position Loop Gain

OW

2E

Pn102

*1

Speed Loop Gain

OW

2F

Pn100

*1

Speed Feed
Forward
Amends

OW

30

Pn109

*1

Position Integration
Time Constant

OW

32

Pn11F

*1

Speed Integration
Time Constant

OW

34

Pn101

*1

Straight Line Accel-
eration/Acceleration
Time Constant

OL

36

Cn-0020

Pn80B

Pn80B/

Pn836

*2

Settings are written regardless of the
communication method.

Straight Line Decel-
eration/Decelera-
tion Time Constant

OL

38

Pn80E

Pn80E/

Pn83C

*3

Filter Time Constant

OW

3A

Cn-002E

Pn811

When “Expo-
nential Accelera-
tion/
Deceleration Fil-
ter” is selected
for filter type.

Settings are writ-
ten regardless of
the communica-
tion method.

Cn-0026

Pn812

When either
“Without filter”
or “Moving
Average Filter”
is selected for
filter type.

Filter Type Selection

OW

03

Bits 8 to B →

Settings are automatically enabled.