7.2 Motions After Switching Motion Commands

7.2.9 Switching from VELO

7-33

Switching Commands during Execution

VELO

TRQ

VELO will immediately switch to TRQ, and the control mode will change from speed
control mode to torque control mode. The moving amount stored in the acceleration/decel-
eration filter will be reset to 0.

After VELO has switched to TRQ, the TRQ command will be executed without
the acceleration/deceleration filter. This is because TRQ is a motion com-
mand for which the acceleration/deceleration filter is disabled.

PHASE

VELO will immediately switch to PHASE, and the control mode will change from speed
control mode to phase control mode. The moving amount stored in the acceleration/decel-
eration filter will be reset to 0.

Switched From

Switched To

Operation

VELO

VELO

TRQ

VELO

TRQ

Speed control mode Torque control mode

TRQ

The reference value of the TRQ command

will be output as is regardless of the

speed when the motion command is

switched.

Motion command
Motion command

response

VELO

VELO

PHASE

VELO

PHASE

Speed control mode Phase control mode

PHASE

The reference value of the PHASE

command will be output as is regardless

of the speed when the motion command

is switched.

Motion command
Motion command

response