2 phase control, 1 motion parameters for phase control, Caution – Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual

Page 320: 1 ) fixed parameters

Advertising
background image

8.2 Phase Control

8.2.1 Motion Parameters for Phase Control

8-8

8.2 Phase Control

Precautions when using SGDV SERVOPACKs of

Σ-V series

8.2.1 Motion Parameters for Phase Control

: These parameters are ignored.

( 1 ) Fixed Parameters

If using the utility functions to adjust the

Σ-V series of SERVOPACKs when the model-following control is

enabled (Pn140.0=1), the SERVOPACK cannot be properly controlled by phase references. When using
phase references, change the settings to the following values.

• Set the model-following control to disabled (Pn140.0=0).
• When using the utility functions for adjustment, select the following modes.

• Advanced Autotuning and Advanced Autotuning by References: Mode=1
• One-parameter Tuning: Tuning mode=0 or 1

CAUTION

No.

Name

Setting Unit

Default Value

Setting Range

0

Selection of Operation Modes

1

0 to 5

1

Function Selection Flag 1

0000h

Bit setting

2

Function Selection Flag 2

0000h

Bit setting

4

Reference Unit Selection

0

0 to 3

5

Number of Digits below Decimal Point −

3

0 to 5

6

Travel Distance per Machine Rotation

Reference unit

10000

1 to 2

31

−1

Linear Scale Pitch
(Linear Motor)

Reference unit

10000

1 to 2

31

−1

8

Servo Motor Gear Ratio

1

1 to 65535

9

Machine Gear Ratio

1

1 to 65535

10

Infinite Length Axis Reset Position
(POSMAX)

Reference unit

360000

1 to 2

31

−1

12

Positive Software Limit Value

Reference unit

2

31

−1

-2

31

to 2

31

−1

14

Negative Software Limit Value

Reference unit

-2

31

-2

31

to 2

31

−1

16

Backlash Compensation Amount

Reference unit

0

-2

31

to 2

31

−1

30

Encoder Selection

0

0 to 3

34

Rated Motor Speed
(Rotary Motor)

min

−1

3000

1 to 32000

Rated Speed
(Linear Motor)

0.1 m/s, 0.1 mm/s

3000

1 to 32000

36

Number of Pulses per Motor Rotation
(Rotary Motor)

pulse

65536

1 to 2

31

−1

Number of Pulses per Linear Scale
Pitch
(Linear Motor)

pulses/linear scale
pitch

65536

1 to 2

31

−1

38

Maximum Number of Absolute Encod-
er Turns Rotation

Rev

65534

0 to 2

31

−1

42

Feedback Speed Moving Average
Time Constant

ms

10

0 to 32