5 ) alarm monitor, 6 ) alarm history monitor – Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual

Page 382

Advertising
background image

10.3 Main Commands and Subcommands

10.3.3 Command Details

10-18

Monitoring Parameters

( 5 ) Alarm Monitor

Description

Reads the alarm that is occurring in the Inverter.

Setting Parameters

Monitoring Parameters

( 6 ) Alarm History Monitor

Description

Reads the Inverter alarm history.

Setting Parameters

Name

Register No.

Setting

Range

Remarks

Command Response Code

IW

08

0 to 8

03: Write User Constant

Command Status

IW

09

Bit

Bit 0 (Command execution flag)

ON during execution

Bit 3 (Command error completed
status)

ON when an error
occurs during com-
mand processing

Bit 8 (Command execution com-
pleted)

ON when command
execution is com-
pleted.

Status

IW

10

Bit

Inverter status

Response Alarm Code

IW

30

0 to FFFFH

Inverter alarm code

Inverter User Constant Number IW

3C

0 to FFFFH

Name

Register No.

Setting Range

Remarks

Command Code

OW

08

0 to 8

04: Alarm Monitor

Name

Register No.

Setting

Range

Remarks

Command Response Code

IW

08

0 to 8

04: Alarm Monitor

Command Status

IW

09

Bit

Bit 0 (Command execution flag)

ON during execution

Bit 3 (Command error completed
status)

ON when an error
occurs during com-
mand processing

Bit 8 (Command execution com-
pleted status)

ON when command
execution is com-
pleted.

Status

IW

10

Bit

Inverter status

Response Alarm Code

IW

30

0 to FFFFH

Inverter alarm code

Inverter Alarm Code

IW

32

0 to FFFFH

The currently occurring alarm is read out

Name

Register No.

Setting Range

Remarks

Command Code

OW

08

0 to 8

05: Alarm History Monitor

Inverter Alarm Monitor Number

OW

32

0 to 3

Alarm monitor number (0 to 3 for Varispeed G7 and
F7, 0 or 1 for VSminiV7)

Advertising