7.2 Motions After Switching Motion Commands

7.2.2 Switching from EX_POSING

7-13

Switching Commands during Execution

EX_POSING

TRQ

EX_POSING will switch to TRQ when the axis stops after deceleration, and the control
mode will change from position control mode to torque control mode.

After EX_POSING has switched to TRQ, the TRQ command will be executed
without the acceleration/deceleration filter. This is because TRQ is a motion
command for which the acceleration/deceleration filter is disabled.

PHASE

EX_POSING will switch to PHASE when the axis stops after deceleration, and the control
mode will change from the position control mode to phase control mode.

Switched From

Switched To

Operation

Cancelled

EX_POSING

operation

EX_POSING

TRQ

EX_POSING

TRQ

EX_POSING

TRQ

Position control mode

Torque control mode

Motion command

Motion command

response

Cancelled

EX_POSING

operation

The reference value of the PHASE

command will be output as is

regardless of the speed at the

time the motion command is

switched.

EX_POSING

PHASE

EX_POSING

PHASE

EX_POSING

PHASE

Position control mode

Phase control mode

Motion command
Motion command

response