5.1 Example Setting of Motion Parameters for the Machine

5.1.6 Acceleration/Deceleration Settings

5-11

Motion Parameter Setting Examples

5.1.6 Acceleration/Deceleration Settings

The acceleration/deceleration can be set to either the rate of acceleration/deceleration or the time required to reach the
rated speed from 0. The settings method used depends on the related parameter settings.
The parameters related to acceleration/deceleration settings are listed in the following table.

Parameter Type

Parameter No.

(Register No.)

Name

Description

Default

Value

Motion Fixed
Parameters

No. 5

Number of
Digits below
Decimal Point

Set the number of digits below the decimal point in the input
reference unit. The minimum reference unit is determined by
this parameter and the Reference Unit Selection (fixed param-
eter 4).
Example:
Reference Unit Selection = mm, Number of Digits below
Decimal Point = 3
1 reference unit = 0.001 mm

No. 34

Rated Motor
Speed

Set the number of rotations when the motor is rotated at the
rated speed (100% speed). Confirm the motor specifications
before setting this parameter.

3000

No. 36

Number of
Pulses per
Motor Rotation

Set the number of pulses (the value after multiplication) per
motor rotation.
Example:
For a 16-bit encoder, set 2

16

= 65536.

65536

Motion Setting
Parameters

OW

03

Bits 4 to 7

Acceleration/
Deceleration
Degree Unit
Selection

Set the unit for acceleration/deceleration.

0: Reference units/s

2

1: ms

1

OL

36

Straight Line
Acceleration/
Acceleration
Time Constant

Set the rate of acceleration or acceleration time constant
according to the setting of OW

03, bits 4 to 7.

• Acceleration/Deceleration Degree Unit Selection is

set to 0 (Reference units/s

2

), set the rate of accelera-

tion.

pulse unit: 1 = 1 pulse/s

2

mm unit: 1 = 1 reference unit/s

2

deg unit: 1 = 1 reference unit/s

2

inch unit: 1 = 1 reference unit/s

2

μm unit: 1 = 1 reference unit/s

2

Example: Number of Digital below Decimal Point = 3

mm unit: 1 = 0.001 mm/s

2

deg unit: 1 = 0.001 deg/s

2

inch unit: 1 = 0.001 inch/s

2

μm unit: 1 = 0.001 μm/s

2

• When Acceleration/Deceleration Degree Unit Selec-

tion is set to 1 (ms), set the time constant to go from 0 to
the rated speed without relation to the reference unit.

0

OL

38

Straight Line
Deceleration/
Deceleration
Time Constant

Set the rate of deceleration or deceleration time constant
according to the setting of OW

03, bits 4 to 7.

• Acceleration/Deceleration Degree Unit Selection is

set to 0 (Reference units/s

2

),

set the rate of deceleration.

pulse unit: 1 = 1 pulse/s

2

mm unit: 1 = 1 reference unit/s

2

deg unit: 1 = 1 reference unit/s

2

inch unit: 1 = 1 reference unit/s

2

μm unit: 1 = 1 reference unit/s

2

• When Acceleration/Deceleration Degree Unit Selec-

tion is set to 1 (ms),
set the time constant to go from 0 to the rated speed with-
out relation to the reference unit.

0