Motorola MPC8260 User Manual

Page 10

Advertising
background image

x

MPC8260 PowerQUICC II UserÕs Manual

MOTOROLA

CONTENTS

Paragraph
Number

Title

Page

Number

7.2.5.2

Address Retry (ARTRY)............................................................................7-11

7.2.5.2.1

Address Retry (ARTRY)ÑOutput.........................................................7-11

7.2.5.2.2

Address Retry (ARTRY)ÑInput ...........................................................7-11

7.2.6

Data Bus Arbitration Signals..........................................................................7-12

7.2.6.1

Data Bus Grant (DBG) ...............................................................................7-12

7.2.6.1.1

Data Bus Grant (DBG)ÑInput ..............................................................7-12

7.2.6.1.2

Data Bus Grant (DBG)ÑOutput............................................................7-12

7.2.6.2

Data Bus Busy (DBB) ................................................................................7-13

7.2.6.2.1

Data Bus Busy (DBB)ÑOutput .............................................................7-13

7.2.6.2.2

Data Bus Busy (DBB)ÑInput................................................................7-13

7.2.7

Data Transfer Signals .....................................................................................7-13

7.2.7.1

Data Bus (D[0Ð63]) ....................................................................................7-13

7.2.7.1.1

Data Bus (D[0Ð63])ÑOutput.................................................................7-14

7.2.7.1.2

Data Bus (D[0Ð63])ÑInput ...................................................................7-14

7.2.7.2

Data Bus Parity (DP[0Ð7]) .........................................................................7-14

7.2.7.2.1

Data Bus Parity (DP[0Ð7])ÑOutput ......................................................7-14

7.2.7.2.2

Data Bus Parity (DP[0Ð7])ÑInput.........................................................7-15

7.2.8

Data Transfer Termination Signals ................................................................7-15

7.2.8.1

Transfer Acknowledge (TA) ......................................................................7-15

7.2.8.1.1

Transfer Acknowledge (TA)ÑInput......................................................7-15

7.2.8.1.2

Transfer Acknowledge (TA)ÑOutput ...................................................7-16

7.2.8.2

Transfer Error Acknowledge (TEA) ..........................................................7-16

7.2.8.2.1

Transfer Error Acknowledge (TEA)ÑInput..........................................7-16

7.2.8.2.2

Transfer Error Acknowledge (TEA)ÑOutput .......................................7-17

7.2.8.3

Partial Data Valid Indication (PSDVAL)...................................................7-17

7.2.8.3.1

Partial Data Valid (PSDVAL)ÑInput ...................................................7-17

7.2.8.3.2

Partial Data Valid (PSDVAL)ÑOutput.................................................7-18

Chapter 8

The 60x Bus

8.1

Terminology .........................................................................................................8-1

8.2

Bus Configuration.................................................................................................8-2

8.2.1

Single MPC8260 Bus Mode.............................................................................8-2

8.2.2

60x-Compatible Bus Mode...............................................................................8-3

8.3

60x Bus Protocol Overview..................................................................................8-4

8.3.1

Arbitration Phase ..............................................................................................8-5

8.3.2

Address Pipelining and Split-Bus Transactions ...............................................8-7

8.4

Address Tenure Operations ..................................................................................8-7

8.4.1

Address Arbitration ..........................................................................................8-7

8.4.2

Address Pipelining............................................................................................8-9

8.4.3

Address Transfer Attribute Signals ................................................................8-10

Advertising