10 60x bus-assigned sdram refresh timer (psrt), 60x bus-assigned sdram refresh timer (psrt) -31, Local bus-assigned upm refresh timer (lurt) -31 – Motorola MPC8260 User Manual

Page 307: Section 10.3.10, Table 10-13 describes lur t þelds

Advertising
background image

MOTOROLA

Chapter 10. Memory Controller

10-31

Part III. The Hardware Interface

Table 10-13 describes LURT Þelds.

10.3.10 60x Bus-Assigned SDRAM Refresh Timer (PSRT)

The 60x bus assigned SDRAM refresh timer register (PSRT) is shown in Figure 10-16.

Table 10-14 describes PSRT Þelds.

Table 10-13. Local Bus-Assigned UPM Refresh Timer (LURT)

Bits

Name Description

0Ð7

LURT

Refresh timer period. Determines the timer period according to the following equation:

This timer generates a refresh request for all valid banks that selected a UPM machine assigned to
the local bus (MxMR[BSEL] =1) and is refresh-enabled (MxMR[RFEN] =1). Each time the timer
expires, a qualiÞed bank generates a refresh request using the selected UPM. The qualiÞed banks
are rotating their requests.
Example: For a 25-MHz system clock and a required service rate of 15.6 µs, given
MPTPR[PTP] = 32, the LURT value should be 12 decimal. 12/(25 MHz/32) = 15.36 µs, which is less
than the required service period of 15.6 µs.

Bit

0

1

2

3

4

5

6

7

Field

PSRT

Reset

0000_0000

R/W

R/W

Addr

0x1019C

Figure 10-16. 60x Bus-Assigned SDRAM Refresh Timer (PSRT)

Table 10-14. 60x Bus-Assigned SDRAM Refresh Timer (PSRT)

Bits Name

Description

0Ð7

PSRT Refresh timer period. Determines the timer period according to the following equation:

This timer generates refresh requests for all valid banks that selected a SDRAM machine assigned to
the 60x bus and is refresh-enabled (PSDMR[RFEN] = 1). Each time the timer expires, all banks that
qualify generate a bank staggering auto refresh request using the SDRAM machine. See
Section 10.4.10, ÒSDRAM Refresh.Ó
Example: For a 25-MHz system clock and a required service rate of 15.6 µs, given MPTPR[PTP] = 32,
the PSRT value should be 12 decimal. 12/(25 MHz/32) = 15.36 µs, which is less than the required
service period of 15.6 µs.

TimerPeriod

LURT

F

MPTC

-----------------

и

ш

ж

ц

=

TimerPeriod

PSRT

F

MPTC

-----------------

и

ш

ж

ц

=

Advertising