Chapter 15. CPM Multiplexing

15-9

Part IV. Communications Processor Module

Figure 15-6. Connection of the Slave Address

Note that the user must program the addresses of the PHYs to be consecutive for each FCC;
that is, the address lines connected to each FCC must be consecutive.

Figure 15-7 describes the interconnection between the receive external multi-PHY bus and
the internal FCC1 and FCC2 receive multi-PHY addresses. The same diagram applies to
the transmit multi-PHY bus using different dedicated parallel I/O pins.

FCC1

FCC2

M

S

M

S

M

S

M

S

5

5

5

5

5

5

5

5

8

5

8

5

0
1
2
3
4

4
3
2
1
0

Pins

These 5 address bits relate to the
slave of FCC1 or FCC2 according to
the programming. Bit 4 is the msb.

NOTE: To use FCC2 as shown, connect the FCC2 address bits reversed with
respect to the pinout address indexes. PHY address pins with no pin
connection should be connected to GND.