5 atm traffic type, 1 peak cell rate traffic type, 2 determining the pcr traffic type parameters – Motorola MPC8260 User Manual

Page 791: Atm traffic type -11, Peak cell rate traffic type -11, Determining the pcr traffic type parameters -11

Advertising
background image

29-11

MPC8260 PowerQUICC II UserÕs Manual

MOTOROLA

Part IV. Communications Processor Module

29.3.3.2 Determining the Number of Slots in a Scheduling Table

The number of time slots in a scheduling table is determined by the channel with the
minimum bit rate; see equation B. The minimum bit rate is achieved when the channel
reschedules only once in a whole table scan. (The maximum schedule advance allowed is
equal to number_of_slots-1.) For example, if the line rate is 155.52 Mbps, the minimum bit
rate is 32 kbps and the CPS is 4, then, according to equation B, the number of slots should
be 1,216.

For the above example, 32 kbps = 155.52 Mbps/((1216-1)

´ 4).

Use equations (A) and (B) to obtain the maximum and minimum bit rates of a scheduling
table. For example, given a line rate = 155.52 Mbps, number_of_slots = 1025, and CPS = 8:

29.3.4 Determining the Time-Slot Scheduling Rate of a Channel

The time-slot scheduling rate of each ATM channel is deÞned by equation C. The resulting
number of APC slots is written in either TCT[PCR], TCTE[SCR] or TCTE[MCR],
depending on the trafÞc type.

29.3.5 ATM TrafÞc Type

The APC uses the cell rate pacing parameters (PCR, SCR, and MCR) to generate CBR,
VBR, ABR, UBR+, and UBR trafÞc. The user determines the kind of trafÞc that is
generated per VC by writing to TCT[ATT] (ATM trafÞc type); see Section 29.10.2.3,
ÒTransmit Connection Table (TCT).
Ó

29.3.5.1 Peak Cell Rate TrafÞc Type

When the peak cell rate trafÞc type is selected, the APC schedules channels to transmit
according to the PCR and PCR_FRACTION trafÞc parameters. Other trafÞc parameters do
not apply to this trafÞc type.

29.3.5.2 Determining the PCR TrafÞc Type Parameters

Suppose a VC uses 15.66 Mbps of the total 155.52 Mbps and CPS = 8. Equation C yields:

Min bit rate =

(B)

(number_of_slots - 1)

´ cells per slot

line rate

Max bit rate = (155.52 Mbps)/8 = 19.44 Mbps

Min bit rate = (155.52 Mbps)/(1024

´ 8) = 18.98 kbps.

Rate [slots] =

(C)

VC rate [bps]

´ cells per slot

line rate [bps]

PCR [slots] = (155.52 Mbps)/(15.66 Mbps

´ 8) = 1.241