Networking via system bus (can) – Lenze EPM−T9XX Modular system User Manual

Page 194

Advertising
background image

Setting of baud rate and node address (node ID)

8

Networking via system bus (CAN)

8.5

L

8.5−2

EDSPM−TXXX−9.0−11/2009

5. Now set the node address with the coding switch for the module. You have

five seconds for this.

– Each node address must be assigned only once.

6. The set node address will be accepted after 5 seconds.

– LED RD goes off.

– The module changes to the pre−operational mode.

)

Note!

The node address can be changed any time with the coding
switch. The setting is accepted after switching on the supply
voltage.

Indices for setting

Index

Name

Possible settings

Important

Lenze

Selection

I100B

h

Node ID

0

0

{1}

63 Display only

System bus node address

I2001

h

CAN baud rate

1

0

{1}

255 Display only

System bus baud rate

0
1
2
3
4
5
6
7
8

1000 kbits/s
500 kbits/s
250 kbits/s
125 kbits/s
100 kbits/s
50 kbits/s
20 kbits/s
10 kbits/s
800 kbits/s

Setting the node address