Parameterising 2/4xcounter module

Encoder with G/RES (modes 28 ... 30)

12

Parameter setting via system bus (CAN) / CANopen

12.4

12.4.15

L

12.4−42

EDSPM−TXXX−9.0−11/2009

epm−t145

Fig. 12.4−56

Counter access of the 2/4xcounter in the modes 28 ... 30

Every HIGH−LOW edge at input IN2 / IN5 (A) increments the counter by 1 if a HIGH
level is applied to input IN3 / IN6 (B) at this time.

epm−t148

Fig. 12.4−57

Signal characteristic of the 2/4xcounter in the mode 28 (upcounter)

Every LOW−HIGH edge at input IN2 / IN5 (A) decrements the counter by 1 if a HIGH
level is applied to input IN3 / IN6 (B) at this time.

epm−t149

Fig. 12.4−58

Signal characteristic of 2/4xcounter in the mode 28 (downcounter)

Counter access

Signal characteristic in mode 28